3 - 2 S-100 • S-105 • S-120 • S-125 Part No. 1268494March 2017Section 3 • Repair ProceduresDisplay ModuleThis table lists the various screens and menu options of the operating software. Some display menus arefor informational purpose only, while others can be changed to alter the machine operating parameters.The key switch must be in the off position before entering the programming mode.Use the or buttons to scroll through the screens.To change parameter values, use the button (to increase) or the button (to decrease) or to selecta setting. Press the button to save the new value to memory. An audible beep will indicate a save tomemory.You must exit the programming mode for the changes to take effect.To Exit Programming Mode:Use the scroll button to scroll through the menu until the screen displays exit, then press theplus button once, and change no to yes, then press the enter button once to accept change.Note: If Programming mode is not exited properly, all machine programming may be lost.Screen orMenu Procedure Description Range or SelectionHour meter (on power up)Engine speedEngine oil pressure PSI (English)Engine oil pressure kPa (metric)Engine temperature °F (English)Engine temperature °C (metric)Primary boom angle sensorTurntable level sensor X°Turntable level sensor Y°Platform angleBattery voltageOperatorMachineStatusUnit ofMeasureandLanguageEngine temperature is notdisplayed until engine isabove 100°F / 38°CDefaultWith key switchon, press theand at thesame time.Hydraulic pressure PSI (English)Hydraulic pressure kPa (metric)Boom angleAxle statusMetric/English measurementsLanguage selectionUse +/- buttons to changeEnglish, German, French,Spanish, Portuguese, Italian,Dutch and Swedish.Deutz 2.9L Turbo (D2.9T)Deutz TD2011L0.4i (DL04i)Perkins 1104D-44T (P1104)Perkins 854F (P854T)With key switchoff, press andhold thebutton and turnthe key switch tothe on position.Release thebutton and press