10 Z-33/18 Part No. 1257143First edition • First PrintingOperator's ManualWork Area SafetyElectrocution HazardsThis machine is not electrically insulated and will notprovide protection from contact with or proximity toelectrical current.ì Obey all local andgovernmental regulationsregarding requiredclearance from electricalpower lines. At a minimum,the required clearancecontained in the chartbelow must be followed.Line Voltage Required Clearance0 to 50KV 10 ft 3.05 m50 to 200KV 15 ft 4.60 m200 to 350KV 20 ft 6.10 m350 to 500KV 25 ft 7.62 m500 to 750KV 35 ft 10.67 m750 to 1000KV 45 ft 13.72 mAllow for platform movement, electrical line swayor sag, and beware of strong or gusty winds.Keep away from themachine if it contactsenergized power lines.Personnel on the groundor in the platform must nottouch or operate themachine until energizedpower lines are shut off.Do not operate the machine during lightning orstorms.Do not use the machine as a ground for welding.Tip-over HazardsOccupants, equipment and materials shall notexceed the maximum platform capacity or themaximum platform capacity of the platformextension.Maximum platform capacity 440 lbs /200 kgMaximum occupants 2The weight of options and accessories, suchas pipe cradles, panel cradles and welders, willreduce the rated platform capacity and must besubtracted from the platform capacity. See thedecals with the options and accessories.If using accessories, read, understand and obeythe decals, instructions and manuals with theaccessory.Do not alter or disable the limit switches.Do not raise or extend the boom unless themachine is on a firm, level surface.Do not depend on the tilt alarm as a level indicator.The tilt alarm sounds in the platform only when themachine is on a severe slope.