55Heat dissipationHeat dissipation is measured in BTU/h, and 1 W equals 3.4121 BTU/h.The heat dissipation of a switch depends on its power consumption. To calculate heat dissipation ofthe switch, assume 90% power consumption is converted to heat, and the efficiency of the powermodule is 90%. Heat dissipation/hour of the switch is 0.9 × (total power consumption of the cardsplus power consumption of the fan tray)/0.9 × 3.4121.For the power consumption of the cards and fan trays of the S9800 Switch Series, see "Powerconsumptions."Temperature and humidityTable 14 Temperature and humidity specificationsItem Operating environment Non-operating environmentTemperature 0°C to 40°C (32°F to 104°F) –40°C to +70°C (–40°F to +158°F)Relative humidity(noncondensing) 5% to 95% 5% to 95%NoiseThe switch fan trays can automatically adjust the fan speed based on the heat dissipation conditionof the switch. The sound pressure levels of the switch vary by fan speed. For more information,see Table 15.Table 15 Sound pressure levelsModel Sound pressure level underroom temperatureSound pressure level when thefan tray operates at full speedS9804 (two fan trays) 59.8 dB 76.3 dBS9810 (two fan trays) 50.5 dB 77.9 dBNOTE:The sound pressure levels are measured according to the method specified in ISO 7779 at thebystander position.Other specificationsTable 16 Other specificationsModel System leakage current standard Fusing current Fireproofingstandard• S9804• S9810• EN60950-1• GB4943• IEC60950-1• UL60950-115 A• EN60950-1• GB4943• IEC60950-1• UL60950-1