Installation ManualH3C SecPath F1000-A Firewall Chapter 1 Product Overview1-3Item DescriptionPhysical dimensions(H × W × D)44 × 436 × 430 mm (1.7 × 17.2 × 16.9 in.), excluding therubber feetAC+ACRated voltage range: 100 VAC to 240 VAC, 50 Hz or 60HzMax voltage range: 90 VAC to 264 VAC, 50 Hz or 60 HzRated current: 1.5 AInputpowerDC+DCRated voltage range: – 60 VDC to –48 VDCMax voltage range: – 72 VDC to –36 VDCRated current: 1.5 AMax powerconsumption 100 WOperating temperature 0°C to 40°C (32°F to 104°F )Operating humidity(non-condensing) 10% to 90%Note:Double data rate synchronous dynamic random access memory (DDR DSRAM) storesthe communication data with the CPU and running system.Flash memory stores application files, exceptional information and configuration files.Boot read only memory (Boot ROM) stores the bootstrap program files.1.2.3 LEDsThe following table describes the LEDs on the front panel of the H3C SecPath F1000-Aand describes how to read their status.Table 1-2 LEDs on the front panel of the H3C SecPath F1000-ALED DescriptionPWR0Power supply unit (PSU) LED:OFF means the PWR0 is not supplying power to the device; ONmeans the PWR0 is supplying power to the device.PWR1PSU LED:OFF means the PWR1 is not supplying power to the device; ONmeans the PWR1 is supplying power to the device.SYSSystem operating status LED:On means the system is operating normally; OFF means thesystem is operating abnormally.