63Displaying running status dataFor diagnosis or troubleshooting, you can use the display diagnostic-information command in any viewto bulk collect running data for multiple modules, rather than using separate display commands (such asdisplay clock, display version, display device, and display current-configuration) to collect runningstatus data module by module.• Save running status data for multiple feature modules. display diagnostic-informationSave or display diagnostic information (Y=save, N=display)? [Y/N]:yPlease input the file name(*.diag)[cfa0:/default.diag]:aa.diagDiagnostic information is outputting to cfa0:/aa.diag.Please wait...Save successfully.To view the content of file aa.diag, execute the more aa.diag command in user view, incombination of the Page Up and Page Down keys.• Display running status data for multiple feature modules. display diagnostic-informationSave or display diagnostic information (Y=save, N=display)? [Y/N]:n================================================================display clock================================================================08:54:16 UTC Fri 11/12/2010==================================================================display version==================================================================…Displaying detailed information about cardsUse the display device verbose command to display detailed information about cards. display device verboseStatus : OKType : RPUMPUA PCB : BSWBA PCB : AMPUA Basic CPLD: 3.0MPUA Extend CPLD: 1.0SWBA CPLD: 1.0MPUA LX30T FPGA: 7.01Driver : 1.0SubCard Num : 5CFCard Num : 2Usb Num : 2