Drawing for the installation of indoor and outdoor unitsNecessary Tools for Installationƽ Torque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽƽSelection of Installation PlacePower SourcePreparationThe above picture is for reference only. Your product may look different.Read this manual before installationExplain the operation of the unit to the user according to this manualNO.0010538926Installation Manual of Room Air ConditionerFACEDOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseInsulating materialPiping hole coverFloor fixing dimensions of the outdoor unitFixing of outdoor unitFix the unit to concrete or blockƽ with bolts(10mm) securely.When fitting the unit to wallƽ surface, roof orrooftop, fix the unit securely in considerationof earthquake and strong wind.If vibration may affect theƽ house, fix the unitby attaching a vibration-proof mat.The marks from toin the figure are thename of the parts.The distance betweenthe indoor unit and thefloor should be morethan 2m or 6 feet.The models adopt HFC free refrigerant R410Amore than10cmmore than 5cmmore than 10cmmore than 10cmmore than15cmmore than 60cmAGƽƽAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowGAttention must be paid tothe pitch of drain hoseX Y XZDimensions(mm/inches)Model x y z140 500 256140 500 256583 319.5113.5 633 340HSU09VHG(DB)-WHSU12VHG(DB)-WHSU18VHG(DB)-WHSU24VHG(DB)-WHammerƽƽƽƽPlace where the distance of more than lm from televisions, radios, wireless apparatusesand fluorescent lamps 3 feet or approximately.ƽIn the case of fixing the remote controller on a wall, place where the indoor unit canreceive signals when the fluorescentƽ lamps in the room are in use.ƽƽƽ A distance markedƽ is available as illustrated in the below figure.Indoor Unit - Select a location that isOutdoor Unit - Select a location that isRobust not causing vibration, where the unit can be supported s ufficiently.Not affected by heat or steam generated in the vicinity, and where the inlet and outlet ofthe unit are not disturbed.Possible to drain easily, and where piping can be connected with the outdoor unit.Where conditioned air can be spread in a room evenly.Less affected by rain or direct sunlight and is sufficiently ventilated.Strong enough to bear the unit, where vibration and noise are not increased.Not causing a nuisance to neighbors due to discharged air or noise.(Unit:mm / inch)(5 1/2)(5 1/2)(4 1/2)(4 1/2)113.5(19 2/3)(19 2/3)(23)(24 7/8)(10 1/16)(10 1/16)(12 5/8)(13 1/2)(1 15/16 inches)(3 15/16inches)(3 15/16 inches)(3 15/16 inches)more than 10cm(3 15/16 inches)(5 7/8 inches)(23 5/8 inches)All wiring to the unit must be in accordance with the National Electric codeand local ordinances.