Drawing for the installation of indoor and outdoor unitsNecessary Tools for InstallationHammerƽ Torque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽƽƽƽƽƽPlace where the distance of more than lm from televisions, radios, wireless apparatusesand fluorescent lamps can be left.ƽIn the case of fixing the remote controller on a wall, place where the indoor unit canreceive signals when the fluorescentƽ lamps in the room are in use.ƽƽƽ A distance markedƽ is available as illustrated in the below figure.Before inserting power plug into receptacle, check the voltage without fail.The power source is the same as theƽ corresponding name plate.Install an exclusive branch circuit of the power.ƽA receptacle shall be set up in a distance where the power cable can bereached.Do not extend the cable by cutting it.ƽSelection of Installation PlacePower SourcePreparationNO.0010536242Installation Manual of Room Air ConditionerFACEDOptional parts for pipingNon-adhesive tapeAdhesive tapeSaddle (L.S) with screwsConnecting electric cablefor indoor and outdoorDrain hoseHeating insulating materialPiping hole coverFloor fixing dimensions of theoutdoor unitFixing of outdoor unitFix the unit to concrete or blockƽwith bolts (10mm) and nuts firmlyand horizontally.When fitting the unit to wallƽsurface, roof or rooftop, fixa supporter securely with nailsor wires in consideration ofearthquake and strong wind.If vibration may affect theƽhouse, fix the unit by attaching avibration-proof mat.The marks from toin the figure are theparts numbers.The distance betweenthe indoor unit and thefloor should be morethan 2m.The models adopt HCFC free refrigerant R410Amore than10cm (3 7/8)more than 10cm(3 7/8)more than 10cm(3 7/8)more than 20cm(7 7/8)more than 15cm(5 7/8)more than 25cm(9 7/8)more than 60cm(23 5/8)AGƽƽAFCEDGBArrangement of pipingdirectionsRear leftLeft RearrightRightBelowGAttention must be paid tothe pitch of drain hoseThe above picture is for your reference only. Your product may look different.Read this manual before installation.Explain the operation of the unit to the user according to this manual.Indoor Unit - Select a location that isOutdoor Unit - Select a location that isRobust not causing vibration, where the body can be supported sufficiently.Not affected by heat or steam generated in the vicinity, where inlet and outlet of theunit are not disturbed.Possible to drain easily, where piping can be connected with the outdoor unit.Where cold air can be spread in a room evenly.Nearby a power receptacle. (Refer to drawings).Less affected by rain or direct sunlight and is sufficiently ventilated.Strong enough to bear the unit, where vibration and noise are not increased.(4 1/2)For:24kNot causing a nuisance to neighbors due to discharged air or noise.(10 1/16)(5 1/2)(19 2/3)(5 1/2)(24 7/8) (4 1/2)(13 1/2)140 500 140256113.5 113.5633340For:09k 12k 18k(Unit:mm / inch)