OperationSleep OperationIf the fan speed is high or medium beforesetting for the sleep, set for low speedafter sleeping.Note to the power failure resume:press the sleep button ten times in five secondsand enter this function after hearing four sounds.And press the sleep button ten times within fiveseconds and leave this function after hearing twosounds.NOTE:With the power failure resume, when setting theTIMER ON, TIMER OFF and TIMER ON/OFF,it’s memorized as shutdown status when resumingafter power out .5. Set the fan speed change when sleepingBefore going to bed, you can simply press theSLEEP button and unit will operate in SLEEPmode and bring you a sound sleep.Use of SLEEP functionAfter the unit starts, set the operation status,then press SLEEP button before which theclock must be adjusted and time being set.Operation Mode1. In COOL,DRY mode1 hours after SLEEP mode starts, temp. willbecome about 2 OF higher than temp.setting. Afteranother 1 hours, temp. rises about 2The unit will run for further 6 hours then stopsTemp. is higher than temp. setting so that roomtemperature won't be too Iow for your sleep.SLEEP operation starts SLEEP operation stopsSLEEPoperation startsSLEEPoperation stopsApprox.6hrs1 hr1 hr1 hr3 hrs3 hrsRises about 2OFRises about 2 OFTemp.settingTemp.settingUnit stopUnit stopIn COOL, DRY modeIn HEAT modeDecreases about 4 O F1 hr2.3.In HEAT mode1 hours after SLEEP mode starts, tempwill become about 4 OF lower than temp.setting. After another 1 hours, tempdecrease about 4 O F further. After moreanother 3 hours, temp. rises about 2 OFfurther. The unit will run for further 3hours then stops. Temp. is lower thantemp. setting so that room temperaturewon't be too high for your sleep.In AUTO modeThe unit operates in corresponding sleepmode adapted to the automatically selectedoperation mode.4. In FAN modeIt has no SLEEP function.POWER/SOFT Operation(1) POWER Operation(2) SOFT Operation4When you need rapid heating or cooling, you can use this function.In COOL mode, fan speed automatically takes high speed ofAUTO fan mode. In HEAT mode, fan speed automatically takesmedium speed of AUTO fan mode.You can use this function when silence is needed for rest or reading.In SOFT operation mode, fan speed automatically takes low speedof AUTO fan mode.Note˖During POWER operation, in rapid HEAT or COOL modethe roomwill show uniform temperature distribution. Long periodSOFT operation will cause effect of not too cool or not too warm.To cancel POWER or SOFT operationPress POWER/SOFT button again, POWER or SOFT disappears.6.HEALTHY OperationHealthy Negative ionsThe anion generator in the airconditioner cangenerate a lot of anion effectively balance thequantity of position and anion in the air and alsoto kill bacteria and speed up the dust sediment inthe room and finally clean the air in the room.OF further.Rises about 2OFDecreases about 4 O F