Indoor unitFix to side bar and lintel a mounting bar, Which is separately sold, and then●fasten the plate to the fixed mounting bar.Refer to the previous article, “ When the mounting plate is●position of wall hole.Make a hole of 70 mm(2 3/4)in diameter, slightly descending to outside the wall.●Install piping hole cover and seal it off with putty after installation●When the mounting plate is first fixed1. Carry out, based on the neighboring pillars or lintels, ato be fixed against the wall, then temporarily fasten the plate with one steel nail.2. Make sure once more the proper level of the plate, by hanging a thread with aweight from the central top of the plate, then fasten securely the plate with theattachment steel nail.3. Find the wall hole location A using a measuring tapeWhen the mounting plate is fixed side bar and lintel1 Fitting of the Mounting Plate and Positioning of the wall HoleLid for rightpipingLid for under piping pipeFix with adhesive tapeLid for left pipingIndoor/outdoor electric cable and drain hose must be bound with refrigerant●[ Other direction piping ]Cut away, with a nipper, the lid for piping according to the piping direction and●then bend the pipe according to the position of wall hole. When bending, becareful not to crash pipes.Connect beforehand the indoor/outdoor electric cable,● and then pull out theconnected to the heat insulation of connecting part specially.proper leveling for the platefirst fixed “, for the2 Making a Hole on the Wall and Fitting the Piping Hole CoverDrawing of pipe3 Installation of the Indoor Unit[ Rear piping ]Draw pipes and the drain hose, then fasten them with the adhesive tape●[ Left· Left-rear piping ]In case of left side piping, cut away, with a nipper, the lid for left piping.●In case of left-rear piping, bend the pipes according to the piping direction to●the mark of hole for left-rear piping which is marked on heat insulation materials.1. Insert the drain hose into the dent of heat insulation materials of indoor unit.2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull itout on the front side, then connect them.3. Coat the flaring seal face with refrigerant oil and connect pipes.Fixing the indoor unit body●In order to fix the body onto the mounting plate,hold up●the body aslant from the underside and then put it downperpendicularly.4 Connecting the indoor/outdoor Electric CableRemoving the wiring coverRemove terminal cover at right bottom corner of indoor unit, then take●off wiring cover by removing its screws.1. Insert from outside the room cable into left side of the wallhole, in which the pipe has already existed.2. Pull out the cable on the front side, and connect the cablemaking a loop.Note When connecting the cable, confirm the terminal number of indoor andoutdoor units carefully. If wiring is not correct, proper operation can notbe carried out and will cause damage to the units.●●●mounting plateWhen connecting the cable after installing the indoor unitWhen connecting the cable before installing the indoor unitWhen you unload the indoor unit, please usebottom of the body outward slightlyand lift the unit until it leaves themounting plate.mounting plateUnloading of indoor unit body●your hand to raise the body, then lift theRemote controller (1)R-03 dry battery (2)Mounting plate (1)Drain hose (1)Ø4X25 Screw (4)Plastic cap (4)Drain-elbow (1)Cushion (4)Pipe supporting plate (1)Accessory partsNOTE˖The thickness of the pipe must be 0.8mm(1/16”) at least.Selection of pipeInsert the cord from the back side of the unit, then pull it out on the front side.Fasten the unit wire harness to the conduit holder using the lock nut.Position the conduit holder to its original state using screw.Conduit holder Cut the 6 slit searCover the connection part with heat insulation materials, cover with adhesive tape.piping with protecting tape.Hang the unit body securely onto the upper notches of themounting plate. Move the body from side to side to verifyits secure fixing.Indoor side Outdoor sideØ70mmWall holeThickness of wallHeat insulationmaterialDrain hosePipingPipe supportingplateIndoor/outdoor electric cablemmmmA=150mmA=150mmmm35mmLiquid pipe (Ø)Gas pipe (Ø)For 18K6.35mm(1/4”)12.7mm(1/2”)Type For 24K9.52mm(3/8”)15.88mm(5/8”)(5 7/8)(5 7/8)(5 7/8) (2 3/4)(2 3/4)Pitch downward for drainage(2 3/4)(3 9/16)HSU24VCK-SMDomestic air conditioner35