6 Subject to change without noticeImportant hintsPlease check the instrument for mechanical damage or looseparts immediately after unpacking. In case of damage we adviseto contact the sender. Do not operate.List of symbols used:Consult the manual High voltageSTOPImportant note GroundPositioning the instrumentAs can be seen from the figures, the handle can be set intodifferent positions:A = carryingB = handle removal and horizontal carryingC = horizontal operatingD and E = operating at different anglesF = handle removalT = shipping (handle unlocked)STOPAttention!When changing the handle position, the instrumentmust be placed so that it can not fall (e.g. placedon a table). Then the handle locking knobs must besimultaneously pulled outwards and rotated to theI m p o r t a n t h i n t sAABBCCDDEETFPUkTPUkTPUk PUk PUk PUk PUk PUkPUkT PUkTPUkTPUkTPUkTHGOPFFDPUkTHGOFFDPUOPFGkTPUkTPUkTKl15pFmax400 VpPUOPFGkTPUOPFGkTPUOPFGkTPUOPFGkTPGkT PUOPFGkTPUOPFGkT PFGkTPUOPFGkTPUOPFGkTPUOPFGkT PUOPFGkTPUOPFGkTHAMEGPUOPFGkTPUOPFGkTPUOPFGkTANALOGDIGITALMIXED SIGNALCOMBISCOPEHM15081 GSa · 1MB150 MHzPUOGkTVOLTS/DIVVHGOPFFDVOLTS/DIVVHGOPFFDVOLTS/DIVVHGOPFFDPUkTHGOPFFDPUkTHGOPFFDPUkTPUkTPUkTPUkTPUkTPUkT PUkTPUkTKl15pFmax400 VpPUOPFGkTINPUTSPUOPFPUOPFPUOPFPUOPF PUOPFC O M B I S C O P EBTTrequired position. Without pulling the locking knobsthey will latch in into the next locking position.Handle mounting/dismountingThe handle can be removed by pulling it out further, dependingon the instrument model in position B or F.SafetyThe instrument fulfils the VDE 0411 part 1 regulations forelectrical measuring, control and laboratory instruments andwas manufactured and tested accordingly. It left the factory inperfect safe condition. Hence it also corresponds to EuropeanStandard EN 61010-1 resp. International Standard IEC 1010-1.In order to maintain this condition and to ensure safe operationthe user is required to observe the warnings and other directionsfor use in this manual. Housing, chassis as well as all measu-ring terminals are connected to safety ground of the mains.All accessible metal parts were tested against the mains with2200 V DC. The instrument conforms to safety class I.The oscilloscope may only be operated from mains outlets witha safety ground connector. The plug has to be installed prior toconnecting any signals. It is prohibited to separate the safetyground connection.Most electron tubes generate X-rays; the ion dose rate of this in-strument remains well below the 36 pA/kg permitted by law.Mathematic functionsNumber of Formula Sets: 5 with 5 formulas eachSources: CH 1, CH 2, Math 1-Math 5Targets: 5 math. memories, Math 1-5Functions: ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,NEG, INVDisplay: max. 2 math. memories (Math 1-5)DisplayCRT: D14-375GHDisplay area (with graticule): 8 cm x 10 cmAcceleration voltage: approx. 14 kVGeneral InformationComponent testerTest voltage: approx. 7 Vrms (open circuit), approx. 50 HzTest current: max. 7 mA rms (short circuit)Reference Potential : Ground (safety earth)Probe ADJ Output: 1 kHz/1 MHz square wave signal 0.2 Vpp(tr ‹ 4 ns)Trace rotation: electronicLine voltage: 105 – 253 V, 50/60 Hz ± 10 %, CAT IIPower consumption: 47 Watt at 230 V, 50 HzProtective system: Safety class I (EN61010-1)Weight: 5.6 kgCabinet (W x H x D): 285 x 125 x 380 mmAmbient temperature: 0° C ...+40° CAccessories supplied: Line cord, Operating manual, 2 Probes 10:1 withattenuation ID (HZ200), Windows Software for control and data transferOptional accessories:HO730 Dual-Interface Ethernet/USBHO740 Interface IEEE-488 (GPIB)HZ70 Opto-Interface (with optical fiber cable)