56 HARDI® N-SERIES 3-PT SPRAYER DIAPHRAGM OPERATOR'S MANUAL6.6 Changing the Valves and Diaphragms (all pumps)Note: It is recommended that if one or more diaphragms and or valvesneed replacing, they should all be replaced. Complete rebuild kits areavailable from HARDI® (check the table below for part numbers).1. Remove the valve cover 1. Before changing the valves 2, note theorientation of the valves so that they are replaced correctly.2. It is recommended to use new O-rings 3 when changing or checkingvalves.3. Remove diaphragm covers 4 to gain access to the diaphragms.4. Remove the diaphragm bolts 5. The diaphragms 6 may now bechanged.5. If fluids have reached the crankcase, regrease the pump thoroughly.Also make sure the drain hole at the bottom of the pump is notblocked.6. Reassemble with torque settings shown below.412356Model 1203(603 similar)423156Model 1303PumpModelValve CoverFt/lb (Nm)DiaphragmBolt Ft/lb (Nm)DiaphragmCover603 34 (46) 18.5 (25) 37 (50)1203/1303 45 (60) 45 (60) 50 (70)Pump model 603 1203 1303Hardi® Part No. 750656 750696 750175