TROUBLE-SHOOTINGOBSERVE PROBLEMD. When ignitor button ispressed there is spark at ODSpilot, but not ignition.E. Gas odor even when controlknob is in the OFF position.F. Slight odor during initialoperation.G. Main burner does not lightafter ODS pilot is lit.H. Delayed ignition of mainburner.I. Main burner backfiring duringcombustion.J. Appliance producesunwanted odors.K. Soot is depositing on logs, infireplace, or in room.POSSIBLE CAUSE1. Gas supply turned off or manualshutoff valve closed.2. Control knob not in PILOTposition.3. Control knob not pressed inwhile in PILOT position.4. Air in gas line.5. ODS pilot is clogged.1. Gas leak.2. Control valve defective.1. Smell coming from the paintcuring on the logs and burnersystem.1. Burner orifice is clogged.2. Inlet gas pressure is too low.3. Gas line obstruction. (pipedope, teflon tape, etc…)1. Burner orifice is clogged.2. Inlet gas pressure is too low.3. Gas line obstruction. (pipedope, teflon tape, etc…)1. Burner orifice is clogged ordamaged.2. Inlet gas pressure is too low.3. Gas line obstruction. (pipedope, Teflon tape, etc…)1. Fresh paint fumes, cleaningagents, pet hair, or other particlesare cycling thru the fireplace whenit is operating.2. Gas leak.1. Logs are not positioned properlyand are obstructing the flame.2. Main burner has accumulateddust or other small particles.REMEDY1. Turn on gas supply or openmanual shutoff valve.2. Turn control knob to PILOTposition then depress knob.3. Press in control knob whilein PILOT position.4. Continue holding downcontrol knob. Repeat ignitingoperation until air is removed.5. Clean ODS pilot.1. Locate and correct all leaks.2. Contact dealer to receivefurther instructions oncorrecting problem.1. Problem will stop after a fewhours of operation. Run theheater with the damper open ifyou have one or open awindow for the first few hours.1. Clean burner orifice andmain burner.2. Contact local gas company.3. Locate and clearobstruction.1. Clean or replace burnerorifice. Clean main burner.2. Contact local gas company.3. Locate and clearobstruction.1. Clean or replace burnerorifice. Clean main burner.2. Contact local gas company.3. Locate and clearobstruction.1. Ventilate room. Stop usingodor causing products whileheater is running.2. Locate and correct all leaks.1. Logs must be repositionedso they do not come in contactwith the flame.2. Clean main burner.20