Diagnostic Error Code FRU/Action086-196-XXXMouse Port interface test halt, errorthreshold exceeded1. Press F3 to review the log file2. Re-start the test to reset the log file086-197-XXXMouse Port interface test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test086-198-XXXMouse Port interface test aborted 1. If a component is called out, make sure itis connected and/or enabled2. Flash the system and re-test3. Go to the ″Undetermined problems″section086-199-XXXMouse Port interface test failed, causeunknown1. Go to the ″Undetermined problems″section2. Flash the system and re-test3. Replace component under function test089-000-XXXMicroprocessor Test Passed 1. No action089-XXX-XXXMicroprocessor failure 1. Microprocessor(s)2. System board089-195-XXXMicroprocessor Test aborted by user 1. Information2. Re-start the test, if necessary089-196-XXXMicroprocessor test halt, error thresholdexceeded1. Press F3 to review the log file2. Re-start the test to reset the log file089-197-XXXMicroprocessor test warning 1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test089-198-XXXMicroprocessor test aborted 1. Flash the system and re-test2. Go to the ″Undetermined problems″section089-199-XXXMicroprocessor test failed, cause unknown 1. If a component is called out, make sureit is connected and/or enabled2. Go to the ″Undetermined problems″section3. Flash the system and re-test4. Replace component under function test170-000-XXXVoltage Sensor(s) Test Passed 1. No action170-0XX-XXXVoltage Sensor(s) failure 1. Flash system2. System boardChapter 7. Symptom-to-FRU index 63