Chapter 6. Symptom-to-FRU Index 79015-198-XXXUSB port test aborted1. If a component is called out, make sure itis connected and/or enabled2. Flash the system and re-test3. Go to the "Undetermined problems"section015-199-XXXUSB port test failed, cause unknown1. Go to the "Undetermined problems"section2. Flash the system and re-test3. Replace component under function test018-000-XXXPCI Card Test Passed1. No action018-0XX-XXXPCI Card Failure1. Riser card, if installed2. System board018-195-XXXPCI Card Test aborted by user1. PCI card2. Information3. Re-start the test, if necessary018-196-XXXPCI Card test halt, error threshold exceeded1. Press F3 to review the log file2. Re-start the test to reset the log file018-197-XXXPCI Card test warning1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test018-198-XXXPCI Card test aborted1. Make sure the component that is calledout is connected and/or enabled2. Flash the system and re-test3. Go to the "Undetermined problems"section018-199-XXXPCI Card test failed, cause unknown1. Go to the "Undetermined problems"section2. Flash the system and re-test3. Replace component under function test018-250-XXXPCI Card Services error1. PCI card2. Riser card, if installed3. System board020-000-XXXPCI Interface Test Passed1. No action020-0XX-XXXPCI Interface error1. PCI card2. Riser card, if installed3. System board020-195-XXXPCI Test aborted by user1. Information2. Re-start the test, if necessary020-196-XXXPCI test halt, error threshold exceeded1. Press F3 to review the log file2. Re-start the test to reset the log fileDiagnostic Error Code FRU/Action