e. Verify that a 25.4 cm (10 in.) SMP Expansion cable is connected betweenport 3 of SMP Expansion Module 2 and port 3 of SMP Expansion Module3.5. Connect the Remote Supervisor Adapter Ethernet port on each server to anetwork or to each other with an Ethernet crossover cable. This connection isneeded so that the Remote Supervisor Adapters can communicate andperform the necessary functions for the two servers to create or delete staticpartitions.6. Route any remaining cables through the cable-management arms.7. Secure the cables in the cable-management arms with the hook-and-loopstraps that come with your server.8. If you are connecting to an IBM RXE-100 Remote Expansion Enclosure, go to“Cabling an RXE-100” for instructions on how to connect the IBM RXE-100 toa 16-way system; then, return here.9. Turn on the primary server and verify operating of the 16-way configurationwhen the following displays on the screen:Secondary Server FoundSecondary Server Merged into PartitionXcel4 (tm) Server Accelerator Cache enabled on Expansion SMP Module 1Xcel4 (tm) Server Accelerator Cache enabled on Expansion SMP Module 2Xcel4 (tm) Server Accelerator Cache enabled on Expansion SMP Module 3Xcel4 (tm) Server Accelerator Cache enabled on Expansion SMP Module 410. See the software documentation that comes with your server to install youroperating system.Important: Do not use ServerGuide ™ to install the operating system thatcomes with your server.Cabling an RXE-100Complete the following steps to connect an IBM RXE-100 Remote ExpansionEnclosure to a 16-way system.1. Turn on the primary server and start the Configuration/Setup Utility program.a. When the message Press F1 for Configuration/Setup appears, press F1.b. Select Advanced Setup from the main menu; then, select Static PartitionSettings.c. Enable Remote Expansion Enclosure.d. Select Save Static Partition Settings and follow the prompts.e. Exit the Configuration/Setup Utility Program.f. Turn off the primary server.8 xSeries 440: 16-way Configuration Supplemental Information