OPF-TH1000D/OPF-RH1000D User’s Guide428.3.2 Setting command@GPM / @SPM Setting time for ignoring video output request signals: Hot Plug mask off setting(only receiver)Function Acquisition SettingFormat @GPM @SPM, timeReturn valueformat@GPM, time @SPM, timeParameter time: If the request signals are repeated in a short cycle, video may not be output. Thisproblem can be solved by setting the ignoring time.0 = OFF [Default]2 to 15 = 2 to 15 secondsExample @GPM@GPM,0Acquires the current setting status.The setting is OFF.@SPM,2@SPM,2Sets the ignoring time to 2 seconds.The setting has been changed to 2 seconds.Related info. -@GIV Acquiring version informationFunction AcquisitionFormat @GIVReturn valueformat@GIV, id, verParameter id: model namever: firmware versionExample @GIV@GIV,OPF-RH1000D ,1.00Acquires the version information of the firmware.The firmware version of the OPF-RH1000D isver.1.00. (for transmitter, the firmware version ofthe “OPF-TH1000D” will be returned.)Related info. 7.2.13 [F90] Version