Instruction ManualInnovative DisplayWorksRCM-2MAINTENANCECleaning• Unplug the cooler before cleaning.• Use a soft cloth or sponge with water or soap (non-corrosive mild detergent). After cleaning, wipe the cooler using adry cloth to prevent the cooler from rusting.• Do not spray water on the cooler, and do not use hard or steel brushes to clean the cooler.• Do not use organic solvents, boiling water, washing powders or acids while cleaning.If the cooler will be in a non-operational state for a long period of time, clean asinstructed above, and keep the door open until interior is dry.REFRIGERATION• The RCM 2 Electric Impulse Cooler utilizes R134a refrigerant.SPECIFICATIONSModel: RCM 2 Electric Impulse CoolerPower Supply (V/Hz): 220V/50Hz or 110V/60HzDimension (WxDxH): 22” x 16.6” x 39.5”Box Dimension (WxDxH): 24.25” x 19” x 43.7”8 9MOVING THE COOLER• Remove all product from the unit.• Secure all loose parts inside the cooler.• Tape the door shut.• Ship the cooler in an upright position.TroubleshootingThe following are NOT malfunctions:Situation CausesLiquid flowing noise within cooler • This is the sound of the cooling agent flowing through the pipes.Refrigeration system is shutdown for longer periodsof time while temperature inside is still very low• This refrigerator is well insulated and can maintain a relatively ambienttemperature.Condensation on glass door • This may be due to a high indoor humidity or the coolers temperature is set toolow. Wipe the door dry with a towel.Prior to calling service, check the following:.Issues SolutionsCooler is not working properly Please check power supply:• Check the electrical outlet for power, and that the plug is properly inserted.• Check to see if the circuit breaker is tripped or the fuse is blown.• Check if the condenser is free of dirt and debris.• Check for low voltageCooler is not keeping product cool • Provide ample space between all products to ensure proper circulation of air.• Keep unit away from direct sunlight or other heating source.• Keep the door closed as often as possible.• Be certain the cooler is not touching external objects or walls.Excessive noise • Be certain the cooler is placed on a level surface.• Be certain the cooler is not touching external objects or walls.Compressor turns on and off frequently • The room temperature is higher than normal.• The door is not closed completely.• The door gasket is not sealed properly.• There is insufficient clearance around the cooler.• The thermostat is not set properly.• The frequency of cycling will be reduced when all of the product reaches the settemperature.After Sales ServiceInformation to provide to your qualified service professional:• Serial number from the interior wall of the cooler;• Coolersʼ installation address and contact information;• Installation location hours and operation;• Nature of problem;• Any reports of power interruptions;• Recent service or maintenance completed on the cooler;• Has the cooler been relocated from original installation location;• Clear access to the cooler;• Coolersʼ instruction manual. |
Related manuals for IDW RCM-2
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine