DRPC-120-BTi Embedded SystemPage 343.10.1 Managed System Hardware SetupThe hardware configuration of the managed system (DRPC-120-BTi) is described below.Step 1: Install an iRIS-2400 module to the IPMI module socket (refer to Section 3.5).Step 2: Make sure at least one DDR3 SO-DIMM is installed in one of the SO-DIMMsockets. If multiple SO-DIMMs are installed, all of the SO-DIMMs must be samesize, same speed and same brand to get the best performance.Step 3: Connect an Ethernet cable to LAN2 RJ-45 connector (Figure 1-2).3.10.2 Using the IEI iMAN Web GUITo manage a client system from a remote console using IEI iMAN Web GUI, follow thesteps below.Step 1: Obtain the IP address of the managed system. It is recommended to use theIPMI Tool on the managed system to obtain the IP address. To use IPMI Tool toobtain IP address, follow the steps below:a. Copy the Ipmitool.exe file to a bootable USB flash drive.b. Insert the USB flash drive to the DRPC-120-BTi.c. The DRPC-120-BTi boots from the USB flash drive.d. Enter the following command: ipmitool 20 30 02 01 03 00 00(there is a space between each two-digit number).e. A serial of number shows. The last four two-digit hexadecimal numbers arethe IP address. Convert the hexadecimal numbers to decimal numbers.Step 2: On the remote management console, open a web browser. Enter the managedsystem IP address in the web browser (Figure 3-19).Figure 3-19: IEI iMAN Web AddressStep 3: The login page appears in the web browser.