IVS-200-ULT2 Embedded SystemPage 16only be carried out by qualified personnel who are familiar with the associateddangers. Air Circulation: Make sure there is sufficient air circulation when installing theIVS-200-ULT2. The IVS-200-ULT2’s cooling vents must not be obstructed byany objects. Blocking the vents can cause overheating of the IVS-200-ULT2.Leave at least 5 cm of clearance around the IVS-200-ULT2 to preventoverheating. Grounding: The IVS-200-ULT2 should be properly grounded. The voltagefeeds must not be overloaded. Adjust the cabling and provide externalovercharge protection per the electrical values indicated on the label attachedto the back of the IVS-200-ULT2.3.2.1 High Surface TemperatureWARNING:Some surfaces of the equipment may become hot during operation.The surface temperature may be up to several tens of degrees hotterthan the ambient temperature. Under these circumstances, theequipment needs to be protected against accidental contact.The equipment is intended for installation in a RESTRICTED ACCESS LOCATION. Access can only be gained by SERVICE PERSONS or by USERS who havebeen instructed about the reasons for the restrictions applied to the locationand about any precautions that shall be taken. Access is through the use of a TOOL or lock and key, or other means ofsecurity, and is controlled by the authority responsible for the location.