4-9ADJUSTMENT ITEM TRANSCEIVER'S CONDITION OPERATION ADJUSTPOINT VALUEPREPARATION 1 • Frequency: 14.1515 MHz• Receive1) Connect the SSG to [ANT1], andthen set it as;Frequency : 14.1515 MHzLevel : +34 dBμ (–73 dBm)Modulation: None2) Connect the millivoltmeter and aspeaker to [EXT-SP].3) Push [MENU].–Push [NOTCH].(To enter to the receiveadjustment menu.)Push [MENU] to enter the Receive adjustment menu.RX-IFT 2 • Display: "RX-IFT"• Receive– –Push [SET].(A beep sounds, andthen another beepssound 5 sec. later)RX TOTAL GAIN 3 • Display: "Total Gain HF POFF"• Receive4 • Display: "Total Gain HF PON"• ReceivePush [SET].(A beep sounds, andthen another beepssound 20 to 30 sec.later)S-METER NOTE: DO NOT change the SSG output level until the beep sounds.5 • Display: "S9 Level HF"• Receive––Push [SET].(A beep sounds, andthen another beepsounds 1 sec. later)6 • Display: "S9+60 Level HF"• Receive• Set the SSG as;Level : +90 dBμ (–17 dBm)Automatically returns to the receive adjustment menu.SETReterns to the adjustment screen.Stores the value and move to the next item.4-9 RECEIVE ADJUSTMENTS (HF BAND)1) Set or modify the adjustment value as specifi ed by rotating [MAIN DIAL].2) Push [SET] to store the value.