5 - 3ADJUSTMENT RECEIVER’SCONDITION OPERATION ADJUSTMENTITEM VALUEBARANTENNA(0.495 MHz)1 NOTE: This procedure (the step "1" and "2") must be done twice.• Frequency: 0.495 MHz• Receiving1) Connect the supplied antennato a signal generator through anappropriate conector adapter, and setit as follows;Frequency : 0.495 MHzLevel : 107 dBμ (0 dBm)Modulation : None2) Gradually move the IC-R6 away fromthe SG until the 11th scale of thesignal strength indicator on the IC-R6LCD disappears.3) Push [V/M] when the 11th scale justdisappears.Push [V/M](the 11thscale is justdisappeared)(1.620 MHz) 2 • Frequency: 1.620 MHz• Receiving1) Set the SSG as;Frequency : 1.620 MHz2) Follow the same procedure as thestep "1."5-3 RECEIVE ADJUSTMENTS1) Select an adjustment item using [BAND]/[TS].2) Set the SSG as specifi ed, then push [V/M] when the 11th scale is just disappeared, to store the adjustment value.STANDARD SIGNAL GENERATORSupplied antennaPush [V/M] when the 11th scale just disappears.Conector adaptorJust disappeared.¤ ADJUSTING BAR ANTENNA