5 - 4ADJUSTMENT ADJUSTMENT CONDITION OPERATION VALUES-meter[Sr]NOTE: “RECEIVE SENSITIVITY” should be adjusted before “S-meter.”Otherwise, “S-meter” will not be adjusted properly.1 ••Set the SSG as;Frequency : Displayed frequencyLevel : −6 dBu (−113 dBm)ReceivingPush [CLR] key to store the adjustment value andselect the next adjustment item.(automaticadjustment)[dF]* Push [Y] to skip this item.[Et]* Push [Y] to skip this item.CTCSSAMPLITUDE(f=5.00 kHz)[C5]NOTE: “DTCS MODULATION BALANCE” (page 5-3) should be adjusted before “CTCSS AMPLITUDE.”Otherwise, “CTCSS AMPLITUDE” will not be adjusted properly.1 •••Set the Modulation Analyzer same as“DEVIATION.”No audio signal is applied to the MIC line.TransmittingRotate [CONTROL DIAL] during transmit toadjust the daviation, then release the [PTT] andpush [CLR] key to store the adjustment value.±0.75 kHz(f=6.25 kHz)[C6]2[dt]* to [D6]* Skip these items. (The adjustment is completed. Turn the power OFF.)¤ ADJUSTMENT (continued)*; These items MUST NOT be modifi ed. Otherwise, the transceiver will not perform properly.All manuals and user guides at all-guides.com