27BOXER combination boiler - Installation and ServicingINSTALLATION38 HANDING OVER7. If a programmer is fitted then draw attention to the UsersInstructions and hand them to the householder.8. Loss of system water pressureExplain that the dial on the control panel indicates thecentral heating system pressure and that if the normalCOLD pressure of the system is seen to decrease over aperiod of time then a water leak is indicated. In this event aregistered local heating installer should be consulted.WARNING.Do not fire the boiler if the pressure has reduced to zerofrom the original setting.9. After installation, commissioning and customer hand-over instructions please complete theappliance log book and leave this with the customer.10. IMPORTANTA comprehensive service should be carried out ANNUALLY.Stress the importance of regular servicing by a Corgiregistered installer.As the installer you may wish to undertake the servicecontract yourself or alternatively offer to the customer thebenefits of the Ideal Care Scheme details of which areoutlined in the householder pack supplied with this boiler.After completing the installation and commissioning of thesystem the installer should hand over to the householderby the following actions:1. Hand the User Instructions to the householder and explainhis/her responsibilities under the relevant nationalregulations.2. Explain and demonstrate the lighting and shutting downprocedures.3. The operation of the boiler and the use and adjustment ofall system controls should be fully explained to thehouseholder, to ensure the greatest possible fuel economyconsistent with the household requirements of both heatingand hot water consumption.Advise the User of the precautions necessary to preventdamage to the system and to the building, in the event ofthe system remaining inoperative during frosty conditions.4. Explain the function and the use of the boiler heating anddomestic hot water controls.5. Explain the function of the boiler fault mode.Emphasise that if a fault is indicated, the boiler should beturned off and a registered local heating installer consulted.6. Explain and demonstrate the function of time andtemperature controls, radiator valves etc., for the economicuse of the system.WATER TEMPERATURESThe design water output temperatures are as follows:Central Heating 82 0C maximumDomestic Hot Water 62 0C maximumLower temperatures can be selected via the CH and DHWthermostats (G and H, see frame 34).37 GENERAL CHECKS - continued5. Set the central heating external controls to OFF. Theburner should go off and the pump continue to run for a 5minutes.The CH led in Off.6. Check the correct operation of the programmer (if fitted)and all other system controls. Operate each controlseparately and check that the boiler operates correctlyWATER CIRCULATION SYSTEM1. With the system COLD, check that the initial pressure iscorrect to the system design requirements.For pre-pressurised systems, this should be 1.0 bar.2. With the system HOT, examine all water connections forsoundness. The system pressure will increase withtemperature rise but should not exceed 2.5 bar.3. With the system still hot, turn off the gas, water andelectricity supplies to the boiler and drain down tocomplete the flushing process.Note. A flushing solution should be used during the flushingprocedure. Flushing solutions, Fernox Superfloc,Sentinel X300 (new systems) or X400 (existingsystems). Refer to Frame 6.4. Refill and vent the system, add inhibitor (see Frame 6),clear all air locks and again check for water soundness.Affix the water treatment warning label, supplied in thehardware pack, in a prominent position on the system, toprevent the use of incorrect water treatment additives.5. Reset the system initial pressure to the designrequirement.6. Balance the system. Refer to Frame 5.7. Finally, set the controls to the User's requirements.Note. The pump will operate briefly as a self-check, onceevery 24 hours regardless of system demand.Knob Setting CH Flow DHW OutletTemp TempoC (oF) oC (oF)Max 82 (180) 62 (144)Min 45 (113) 40 (104)INSTALLATION