6Henrad SE FF - InstallationGENERALDetailed recommendations are contained in the following BritishStandard Codes of Practice:BS. 6891 Low pressure installation pipes.BS. 6798 Installation of gas fired hot water boilers of ratedinput not exceeding 60 kW.BS. 5449 Forced circulation hot water systems.BS. 5546 Installation of gas hot water supplies for domesticpurposes (2nd Family Gases)BS. 5440:1 Flues (for gas appliances of rated input notexceeding 60 kW)BS. 5440:2 Ventilation (for gas appliances of rated input notexceeding 60 kW)Health & Safety Document No. 635The Electricity at Work Regulations, 1989.The manufacturer’s notes must NOT be taken, in any way, asoverriding statutory obligations.IMPORTANT. These appliances are CE certificated for safetyand performance. It is, therefore, important that no externalcontrol devices, e.g. flue dampers, economisers etc., aredirectly connected to these appliances unless covered bythese Installation and Servicing Instructions or as otherwiserecommended by Caradon Plumbing Limited in writing. If indoubt please enquire.Any direct connection of a control device not approved byCaradon Plumbing Limited could invalidate the certificationand the normal appliance warranty. It could also infringe theGas Safety Regulations and the above regulations.LOCATION OF BOILERThe boiler must be installed on a flat and vertical wall, capableof adequately supporting the weight of the boiler and anyancillary equipment.The boiler may be fitted on a combustible wall and insulationbetween the wall and the boiler is not necessary, unlessrequired by the local authority.The boiler must not be fitted outside.Timber Framed BuildingsIf the boiler is to be fitted in a timber framed building it shouldbe fitted in accordance with the Institute of Gas Engineeringdocument IGE/UP/7 : 1998.INTRODUCTIONSE 30-80 FF are fully automatically controlled, wall mounted,low water content, balanced flue, fanned super efficientcondensing gas boilers. They are spot-rated to provide centralheating outputs of 8.8 kW (30,000 Btu/h) to 23.4 kW (80,000Btu/h).Due to the high efficiency of the boiler a plume of water vapourwill form at the flue terminal during operation.The boiler casing is of white painted mild steel with a drop- downcontrol pod door. The controls pod, also of white painted mild steel,has fixed sides and a removable bottom panel.The boiler thermostat is located behind the controls pod door.The heat exchanger is of aluminium.Note.These boilers cannot be used on systems which includegravity circulation.The boilers are suitable for connection to fully pumped, open ventedor sealed water systems. Adequate arrangements for completelydraining the system by provision of drain cocks MUST be providedin the installation pipework.OPTIONAL EXTRA KITSRoof Flue Kit For vertical flue connection.Extension Ducts (1m) Up to 3.0m (122").Flue Elbow Kits 90 Degree pack45 Degree pack (2 per pack)SAFETYGas Safety (Installation and Use) Regulations, 1994,amendments 1996 or rules in force.It is law that all gas appliances are installed and serviced by aCORGI registered installer (identified by ) in accordance withthe above regulations. Failure to install appliances correctly couldlead to prosecution. It is in your own interest, and that of safety, toensure the law is complied with.The installation of the boiler MUST also be in accordance with thelatest I.E.E (BS 7671) Wiring Regulations, local buildingregulations, bye-laws of the local water authority, the buildingregulations and the Building Standards (Scotland) and anyrelevant requirements of the local authority.