5Mexico Super 100 FF & 125 FF - InstallationGAS SAFETYGas Safety (Installation and Use) Regulations, 1994,and amendments 1996 or the rules in force.It is law that all gas appliances are installed by a CORGIregistered installer (identified by ) in accordance with theabove regulations. Failure to install appliances correctly couldlead to prosecution. It is in your own interest, and that of safety,to ensure the law is complied with.The installation of the boiler MUST also be in accordance withthe latest I.E.E (BS 7671) Wiring Regulations, local buildingregulations, bylaws of the local water authority, the BuildingRegulations and Building Standards (Scotland) and anyrelevant requirements of the local authority.Detailed recommendations are contained in the followingBritish Standard Codes of Practice:BS. 6891 Low pressure installation pipes.BS. 6798 Installation of gas fired hot water boilers of ratedinput not exceeding 60 kW.BS. 5449:1 Forced circulation hot water systems (small boreand microbore domestic central heatingsystems).BS. 5546 Installation of gas hot water supplies for domesticpurposes (2nd Family Gases).BS. 5440: 1 Flues for gas appliances of rated input notexceeding 60 kW.BS. 5440: 2 Ventilation for gas appliances of rated input notexceeding 60 kW.BS 7593 Treatment of water in Domestic Hot WaterCentral Heating Systems.GENERALHealth and Safety Document No. 635.The Electricity at Work Regulations, 1989.Manufacturer’s notes must NOT be taken in any way asoverriding statutory obligations.IMPORTANT. These appliances are certificated by the BritishStandards Institution for safety and performance. It isimportant, therefore, that no external control devices, e.g. fluedampers, economisers etc., are directly connected to theseappliances unless covered by these Installation and ServicingInstructions or otherwise recommended by Caradon PlumbingLimited in writing. If in doubt please enquire.Any direct connection of a control device not approved byCaradon Plumbing Limited could invalidate the BSICertification and the normal appliance warranty. It could alsoinfringe the Gas Safety Regulations and the above regulationsor other statutory requirements.LOCATION OF BOILERThe boiler must be installed on a flat and level floor, capable ofadequately supporting the weight of the boiler and any ancillaryequipment.The boiler may be fitted on a combustible floor.Insulation is not necessary, unless required by the localauthority.The boiler must not be fitted outside.Timber Framed BuildingsIf the boiler is to be fitted in a timber framed building it shouldbe fitted in accordance with the Institute of Gas Engineersdocument IGE/UP/7 : 1998.1. This appliance is NOT suitable for use in adirect hot water system.2. If the boiler is to be used on a sealed system,an Overheat Thermostat Kit is available andmust be installed in accordance with theinstructions supplied with the kit.Dimension A B100 FF 299mm (11 3/4 ") 533mm (21")125 FF 373mm (14 5/8 ") 600mm (23 5/8 ")1 BOILER WATER CONNECTIONS