16 Mexico Super FF440 - FF480 - Installation & ServicingINSTALLATIONSIDE FLUE OUTLET22 FITTING THE FLUE ASSEMBLYA. Inside fitting.If the flue assembly cannot be fitted from the outside, proceed as follows:1. Insert the flue assembly through the hole farenough to allow the rubber seal to unfoldcompletely and form an adequate seal on theoutside wall.2. Ensure the notch is at the top. This will aid thelocation of the studs into the boiler back panel.3. Proceed to Frame 25, item B.B. Outside fitting.Proceed to Frame 25, item A.23 FITTING THE SIDE OUTLET PLATESNote. If the boiler is fitted closer than 25mm to the side wallthe side outlet plate must be fitted now.1. Split the side outlet plate into 2 down the split line.2. Fit the 2 halves of the side outlet plate to the wall,ensuring they are behind the boiler sealing ring.24 LOCATING THE BOILERA. If the flue assembly can be fitted from the outside, proceedas follows:1. Move the boiler into position, ensuring that the flueoutlet is in line with the wall opening.2. Insert the flue assembly, ensuring that the flue slidesinto the flue extension and the 3 sealing ring studslocate into the boiler.B. If the flue assembly has been fitted from the inside,proceed as follows:Move the boiler into position, ensuring that the flueslides into the flue extension tube and the 3 sealingring studs locate into the boiler back panel.1. Secure the flue to the boiler, using the 3M5 wing nuts provided.2. Fit the medium length extension tube (withring) to the flue elbow, rotate in the bayonetslot and secure with the M4 screw.3. Engage the extension tube into the flueoutlet, connect the elbow to the fan outletand secure with the M4 screw.Note.The sealing plate studs will locate in the backpanel one way only. This will ensure that theterminal is correctly aligned.25 CONNECTING THE FLUE TO THE BOILERSIDE FLUE OUTLET