CM-140 GE / CB-140 GE6.5.2 Internal Trigger GeneratorCreate a trigger signal and trigger the cameraRegister ValueAddress0xA040 Trigger Mode 1 = Pre-Select (PS)0xB000 Clock Choice 1 = Pixel Clock0xB004 Counter Dividing Value 1987 = 1/1988 dev(Line Rate)0xB008 Length Counter 0 1000 Clocks0xB00C Start point Counter 0 100 Clocks0xB010 Repeat Count 0 0 = Free Run0xB014 End point Counter 0 500 Clocks0xB018 Counter Clear 0 0 = No Clear0xB058 CAMERA TRIGGER Selector 11 = pulse generator 0LUT(Cross point switch)12bitCountePulse Generator 2(20bit Counter)Pulse Generator 1(20bit Counter)Pulse Generator 0(20bit Counter)LUT12bitPulse Generator 3(20bit Counter)LVAL INDVAL INFVAL INEEN INOPT IN 1OPT IN 2Soft Trigger 0Soft Trigger 1Soft Trigger 2Soft Trigger 3 ( Cross Point Switch )Trigger 0Trigger 1OPT OUT 1OPT OUT 2Time Stamp ResetCounter25 MHzPixel Clock(65MHz)Li ne Rat e 32. 696KHzPulse Generator 0100 Line500 Line1000 LineoutputPulse Generator 0100 Line500 Line1000 LineoutputFig.9. Pulse Generator 0 timing Example 2- 15 -