GO-5000M-PGE / GO-5000C-PGE- 21 -6.3.3 Characteristics of optical interfaceThe relationship of the input signal to the output signal through the optical interface is as follows.User Power(VCC)3.3V 5V 12V 24VTime Delay Rise TDR (us) 0.54 0.54 0.62 0.68Rise Time RT (us) 1.2 1.2 2 3Time Delay Fall TDF (us) 1.5 1.5 2.4 2.1Fall Time FT (us) 3.6 3.4 4.5 6.8Fig.10 Optical interface characteristics6.4 Pulse GeneratorThe GO-5000-PGE has a frequency divider using the pixel clock as the basic clock and two pulsegenerators. In each Pulse Generator, various Clear settings are connected to GPIO.The following shows Pulse Generator default settings.Table-8 Pulse Generator default settingsDisplay Name ValueClock Pre-scaler 1Pulse GeneratorSelectorPulse GeneratorLength StartPointEndPointRepeatCountClearSourceClearInverterClearActivationClearSyncMode- Pulse Generator 0 1 0 1 0 Off True Off Async Mode- Pulse Generator 1 1 0 1 0 Off True Off Async ModeNote: When Pulse Generator Repeat Count is set to “0”, the camera is operating in free-running mode.However, based on the above default setting, Length=1, Start Point=0 and End Point=1, Pulse Generator stops atHigh output. Therefore, if Start Point=0 and End Point=1 are configured, Length should be “2” as the minimumactive width.GO-5000270ΩUserPowerOutput lineVoltage