GO-5000M-PGE / GO-5000C-PGE- 24 -6.4.9 Pulse Generator Clear SourceThe following clear source can be selected as the pulse generator clear signal.Table-10 Pulse generator clear sourcePulse GeneratorClear SourceitemDescriptionLow Connect Low level signal to Clear Source for the selected pulse generator.Default settingHigh Connect High level signal to Clear Source for the selected pulsegenerator.Frame Trigger Wait Connect Frame Trigger Wait signal to Clear Source for the selected pulsegenerator.Frame Active Connect Frame Active signal to Clear Source for the selected pulsegenerator.Exposure Active Connect Exposure Active signal to Clear Source for the selected pulsegenerator.FVAL Connect FVAL signal to Clear Source for the selected pulse generator.LVAL Connect LVAL signal to Clear Source for the selected pulse generator.PulseGenerator0OutConnect Pulse Generator 0 output to Clear Source for the selected pulsegenerator.PulseGenerator1OutConnect Pulse Generator 1 output to Clear Source for the selected pulsegenerator.Line 5 Opt 1 In Connect Opt 1 In signal to Clear Source for the selected pulse generator.Nand 0 Out Connect NAND 0 output signal to Clear Source for the selected pulsegenerator.Nand 1 Out Connect NAND 1 output signal to Clear Source for the selected pulsegenerator.Note:The pulse generator output cannot be used as the clear input to the same pulse generator. Referto “6.2.7.2. Table 10 ”.