— 32 —Trigger ControlThe camera allows the following controls to be performed via external trigger signals.• The settings for exposure control and triggers are related to each other. Be sure toconfigure the settings described in “ExposureMode” .GO-5100MP-PGEShortest Repetition Period for TriggersThe reciprocal of the maximum frame rate is the time required to output one frame. Theshortest repetition periods for triggers cannot be lower than that value.The above table indicates the shortest trigger periods for when [TriggerOverLap] is set to[Readout]. When [TriggerOverLap] is set to [Off], even when the exposure time is shorterthan the frame period, the cycle may be extended.TriggerSelector DescriptionFrameStart Start exposure in response to the external trigger signal input. Selectthis to perform exposure control using external triggers.AcquisitionStart Start image acquisition in response to the external trigger signal input.AcquisitionEnd Stop image acquisition in response to the external trigger signal input.AcquisitionTransferStart Output acquired images at a specified timing in response to anexternal trigger signal input.* There is a limit to the number of image frames that can be storedinternally. The limits for each image format are as follows. Acquiredimages must be output to avoid exceeding these limits.8 bit: Up to 7 frames10 bit: Up to 3 frames12 bit: Up to 3 frames8bit 10bit packed 10bitFull 44.1 ms 66.1 ms 88.1 msROI 2/3 (Height = 1370) 29.4 ms 44.1 ms 58.7 msROI 1/2 (Height = 1028) 22.0 ms 33.1 ms 44.1 msROI 1/4 (Height = 514) 11.0 ms 16.6 ms 22.1 msROI 1/8 (Height = 256) 5.52 ms 8.27 ms 11.0 msBinning Vertical 2 28.2 ms 55.3 ms 55.3 msScanning rangeShortest period of trigger