J-20014.11 Panel Displays T--OHWARNING: RISK OF HYPERTHERMIA (OVER-HEATING)CAUSING SEVERE INJURY, BURNS, OR WELTS.!Water temperature is above acceptable limits. DO NOTENTER SPA! Water temperature has reached 112°F (44°C).The Jets Pump 1 has activated to circulate water throughheater. Contact your authorized Jacuzzi dealer or qualified servicetechnician. The display will alternate between “T--OH” and the currentwater temperature.Note: As a safety measure, the red lights of the spa will flash on and offas an indication that the spa is an overheat condition.To correct condition:• Remove the spa’s cover and allow your spa to cool down.• Program the heater settings for Economy Mode (page 31).• If the condition persists, contact your authorized Jacuzzi dealer.14.12 Panel Displays H--OHWARNING: RISK OF HYPERTHERMIA (OVER-HEATING)CAUSING SEVERE INJURY, BURNS, OR WELTS.!Hi-limit temperature is above acceptable limits. DO NOTENTER SPA! Water temperature has reached 112°F (44°C).The Jets Pump 1 has activated to circulate water throughheater. Contact your authorized Jacuzzi dealer or qualified servicetechnician. The display will alternate between “H--OH” and the currentwater temperature.Note: As a safety measure, the red lights of the spa will flash on and offas an indication that the spa is an overheat condition.14.13 Panel Displays (-- -- -- --)WARNING: RISK OF HYPERTHERMIA (OVER-HEATING)CAUSING SEVERE INJURY, BURNS, OR WELTS.!Water temperature is above acceptable limits. DO NOTENTER SPA! The safety “Watchdog” software has beentriggered and the spa is deactivated. A problem has beendetected which could cause damage to the spa or its components. Thedisplay will alternate between “-- -- -- --” and the scrolling message“WATCHDOG CALL FOR SERVICE” as long as the error exists.Contact your authorized Jacuzzi dealer or qualified service technician.Note: As a safety measure, the red lights of the spa will flash on and offas an indication that the spa is in watchdog condition.50