17PERFORMANCE DATA SHEETSBase Grille Water Filtration SystemModel T2WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)Model T2WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. Theconcentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to thepermissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).■ It is essential that operational, maintenance, and filterreplacement requirements be carried out for the product toperform as advertised.■ Use replacement filter T2RFWG2, part #4396841.Model T2WG2L: Style 1 – When the filter indicator reads 10%,order a new filter. When the indicator reads 0%, it isrecommended that you replace the filter.Style 2 – When the filter indicator changes from green to yellow,order a new filter. When the indicator changes from yellow to red,it is recommended that you replace the filter.Style 3 – When the water filter status display changes from“GOOD” to “ORDER,” order a new filter. When the filter indicatorreads “REPLACE,” it is recommended that you replace the filter.Style 4 – Press FILTER to check the status of your water filter. Ifthe filter indicator light is yellow, order a new filter. If the filterindicator light is red, it is recommended that you replace the filter.Model T2WG2: Change the water filter cartridge every 6 months.If the water flow to the water dispenser or ice maker decreasesnoticeably before 6 months have passed, replace the water filtercartridge more often.■ These contaminants are not necessarily in your water supply.While testing was performed under standard laboratoryconditions, actual performance may vary.■ The product is for cold water use only.■ Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before or after thesystem.■ Refer to the “Warranty” section for the Manufacturer’s name,address and telephone number.■ Refer to the “Warranty” section for the Manufacturer’s limitedwarranty.Application Guidelines/Water Supply ParametersSystem tested and certified by NSF International against NSF/ANSIStandard 42 for the reduction of Chlorine Taste and Odor, ParticulateClass II*; and against NSF/ANSI Standard 53 for the reduction of Mercury,Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.Substance ReductionAesthetic EffectsNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum %ReductionAverage %ReductionChlorine Taste/OdorParticulate Class II * 50% reduction85% reduction2.0182 mg/L1333333 #/mL2.0 mg/L ± 10%At least 10,000 particles/mL0.06 mg/L6600 #/mL** 0.0536 mg/L2325 #/mL97.0399.5197.3499.83ContaminantReductionNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum %ReductionAverage %ReductionLead: @ pH 6.5***Lead: @ pH 8.5***0.010 mg/L0.010 mg/L0.1533 mg/L0.1400 mg/L0.15 mg/L ± 10%0.15 mg/L ± 10%0.0005 mg/L0.0007 mg/L0.0005 mg/L0.0006 mg/L99.6799.5099.6799.57Mercury: @ pH 6.5Mercury: @ pH 8.50.002 mg/L0.002 mg/L0.0058 mg/L0.0059 mg/L0.006 mg/L ± 10%0.006 mg/L ± 10%0.0002 mg/L0.0005 mg/L0.0002 mg/L0.0003 mg/L96.5491.5796.5494.92Benzene 0.005 mg/L 0.0154 mg/L 0.015 mg/L ± 10% 0.0012 mg/L 0.0006 mg/L 92.22 96.34O-Dichlorobenzene 0.6 mg/L 1.7571 mg/L 1.8 mg/L ± 10% 0.0250 mg/L 0.0066 mg/L 98.58 99.63Toxaphene 0.003 mg/L 0.015 mg/L 0.015 mg/L ± 10% 0.001 mg/L 0.001 mg/L 93.33 93.33Carbofuran 0.04 mg/L 0.0819 mg/L 0.08 mg/L ± 10% 0.0400 mg/L 0.0213 mg/L 51.13 74.00Water SupplyWater PressureWater TemperatureService Flow RateCity or Well30 - 120 psi (207 - 827 kPa)33° - 100°F (0.6° - 37.8°C)0.85 gpm (3.2 Lpm) @ 60 psi******Class II particle size: 1 um to <5 umTest requirement is at least 100,000 particles/mL of AC Fine Test Dust.Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.® NSF is a registered trademark of NSF International.