16PERFORMANCE DATA SHEETSInterior Water Filtration SystemModel UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. Theconcentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to thepermissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F ± 5°F(20°C ± 3°C).■ It is essential that operational, maintenance, and filterreplacement requirements be carried out for the product toperform as advertised.■ The disposable water filter should be replaced at least every6 months.■ The filter monitor system measures the amount of water thatpasses through the filter and alerts you to replace the filter.When 90% of the filter’s rated life is used, the yellow (Order)light comes on. When 100% of the filter’s rated life is used, thered (Replace) light comes on, and it is recommended that youreplace the filter. For models without filter status lights,replace the filter every 6 months. Use replacement filtermodel UKF8001AXX-750. 2010 suggested retail price of$44.99 U.S.A./$49.95 Canada. Prices are subject to changewithout notice.■ The product is for cold water use only.■ Do not use with water that is microbiologically unsafe or ofunknown quality without adequate disinfection before or afterthe system. Systems certified for cyst reduction may be usedon disinfected waters that may contain filterable cysts.■ Refer to the “Water Filtration System” section for theManufacturer’s name and telephone number.■ Refer to the “Warranty” section for the Manufacturer’s limitedwarranty.Application Guidelines/Water Supply ParametersSystem tested and certified by NSF International against NSF/ANSI Standard 42 for thereduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSIStandard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, p-Dichlorobenzene,Carbofuran, Toxaphene, Cysts, Turbidity, Asbestos, Tetrachloroethylene and Lindane.Substance ReductionAesthetic EffectsNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum%ReductionAverage%ReductionChlorine Taste/OdorParticulate Class I * 50% reduction85% reduction2.00 mg/L14,000,000 #/mL2.0 mg/L ± 10%At least 10,000particles/mL0.06 mg/L370,000 #/mL ** 0.050625 mg/L196,666 #/mL97.00%97.40%97.52%99.00%ContaminantReductionNSF ReductionRequirementsAverageInfluentInfluent ChallengeConcentrationMaximumEffluentAverageEffluentMinimum%ReductionAverage%ReductionLead: @ pH 6.5Lead: @ pH 8.50.010 mg/L0.010 mg/L0.150 mg/L †0.150 mg/L †0.15 mg/L ± 10%0.15 mg/L ± 10%< 0.001 mg/L< 0.001 mg/L< 0.001 mg/L< 0.001 mg/L>99.30%>99.30%>99.30%>99.30%Mercury: @ pH 6.5Mercury: @ pH 8.50.002 mg/L0.002 mg/L0.006 mg/L0.0059 mg/L0.006 mg/L ± 10%0.006 mg/L ± 10%0.0005 mg/L0.0018 mg/L0.0003 mg/L0.00073 mg/L91.70%69.20%95.00%88.10%Benzene 0.005 mg/L 0.0133 mg/L 0.015 mg/L ± 10% 0.0005 mg/L 0.0005 mg/L 96.10% 96.30%p-Dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >99.80% >99.80%Carbofuran 0.040 mg/L 0.0753 mg/L 0.08 mg/L ± 10% 0.027 mg/L 0.008 mg/L 64.60% 73.45%Toxaphene 0.003 mg/L 0.015 mg/L 0.015 ± 10% < 0.001 mg/L < 0.001 mg/L >93.3% >93.3%Atrazine 0.003 mg/L 0.0102 mg/L 0.009 mg/L ± 10% 0.0027 mg/L 0.00105 mg/L 76.30% 89.40%Asbestos >99% 126.5 MF/L 10 7 to 10 8 fibers/L †† < 0.17 MF/L < 0.17 MF/L >99.99% >99.99%Live Cysts ‡Turbidity>99.95%0.5 NTU122,500 #/L10.5 NTU50,000/L min.11 ± 1 NTU< 1 #/L ‡0.30 NTU< 1 #/L ‡0.125 NTU>99.99%97.30%>99.99%98.80%Lindane 0.0002 mg/L 0.0019 mg/L 0.002 ± 10% < 0.00016 mg/L 0.000035 mg/L 91.80% 97.90%Tetrachloroethylene 0.005 mg/L 0.015 mg/L 0.015 mg/L ± 10% < 0.0005 mg/L < 0.0005 mg/L >96.6% >96.6%Water SupplyWater PressureWater TemperatureService Flow RateCity or Well35 - 120 psi (241 - 827 kPa)33° - 100°F (1° - 38°C)0.78 gpm (2.9 L/min.) @ 60 psi***†††‡Class I particle size: >0.5 to <1 umTest requirement is at least 100,000 particles/mL of AC Fine Test Dust.These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.Fibers greater than 10 um in lengthBased on the use of Cryptosporidium parvum oocysts® NSF is a registered trademark of NSF International.