12Return Spring AdjustmentThe return spring is adjusted at the factory andshould not need further adjustment. If adjustmentis deemed necessary, follow the steps belowwhile referring to Figure 12:1. Unplug the machine from the power source.2. Loosen two hex nuts (A). Do not remove.Do not remove the coil springcover (Step 3). The torsion spring will uncoiland can cause serious injury.3. Firmly hold the coil spring cover (B).4. Pull out the cover and rotate until the pin (C)on the return spring plate engages the nextnotch in the coil spring cover. Turn the coverclockwise to decrease tension and counter-clockwise to increase tension.5. Tighten two hex nuts (A). Do not over-tighten.Nuts should not contact the housing whentight. The hex nuts should be tightenedagainst each other.Work LightInstall a light bulb, no larger than 60 watts into thesocket accessed from beneath the head. Therocker switch controls the light switch (D, Fig. 12).Table Tilt AdjustmentTo tilt the table (refer to Figures 13 and 14):In the following steps, DO NOT OVERLOOSEN. This could result in the tableassembly to separate from the column, falland cause injury.1. Using a 15/16" wrench, loosen the hex capscrew (B), located under the table, about oneturn.2. Pull the locator pin out.The pin may be seated quite tight; in whichcase turn the hex nut (B) clockwise with a3mm hex wrench to assist in extracting thepinNote: When the table is in any position otherthan level (0 degrees), the locator pin is notused.3. Tilt the table to the desired angle by aligningthe scale (in degrees) on the table (C) to themarker at the base of the bracket (D).4. Tighten the hex cap screw (A).Figure 12Figure 13Figure 14