14Electrical Connections WARNING!All electrical connections must be done by aqualified electrician!Failure to comply may result in loss ofproperty and/or serious injury!• JWBS-20 is rated at 2 HP, 1Ph, 230Vonly.A plug needs to be purchased for the bandsawthat matches the outlet you intend to use (A,Fig. 23).Confirm power at the site is the same as thesaw before making any electrical connections.Review the electrical schematic on page 26.The on/off switch (B, Fig. 24) is thermallyprotected. If the saw motor is overloaded, or amomentary interruption of electrical current issensed, the saw will shut off. Allow a fewminutes for the saw to cool down and reset bypushing the off button.MaintenanceKeep bearing guides clean and free of build up.Do not let saw dust build up in the upper andlower wheel housings. Vacuum out frequently.Keep the brake switch, located in the lowerwheel housing, clean and free of saw dust.Connect the bandsaw to a JET dust collectionsystem.Clean and grease the raising/lowering rack forthe upper bearing guides if it becomes difficultto raise, or lower.Clean, and oil the tensioning mechanism if itbecomes difficult to adjust.Vacuum out the motor fan cover.