FX-383VFig 2A. ON Switch – Starts the motor.B. OFF Switch – Stops the motor. As the power still exists,pressing ON will restarts the machine.C. Emergency Stop Switch – Stops the machineimmediately. As the machine is without any power. Turnthe switch clockwise to unlock the switch before startingthe machine.NOTE: To restart the machine, 5 to 7 seconds of waitingis needed for the inverter to release the current.D. Reverse Switch – Reverses the spindle rotation. Used forexecuting a tapping operation.E. Tachometer–Displays the rate of spindle rotation in RPM.F. Spindle Speed Control knob – Changes the speed ofspindle rotation.G. Pump Switch – Starts the coolant flow for cutting.H. Drilling/Tapping Selector – Selects the mode of operation.Fig 3The coolant tank (Fig 3) holds coolant, which pumped to thework piece for cooling and lubricating while cutting. Beforethe operation of a new machine, add coolant to the coolanttank. When iron filings clog the screen, cleaning will berequired. Before cleaning, take off the screen and drain outthe coolant.Fig 4The machine head (Fig 4) can be rotated 360° around thecolumn. It allows more flexibility in work piece sizes.Turn off the machine.Unlock the head handles (I–Fig. 2).Use the riser handle to raise or lower the head. Firmly gripthe head and push left or right to rotate the head.Lock the head handles (I).Always keep the machine head locked after the height ofhead is set as requirement.Warning!Failure to lock the head handles may result in damage of themachine and personal injury.