Jetter AG Technical specifications | 4JX3-BN-EC User Manual 12 / 86Parameter Values StandardsRF field, amplitude-modulatedFrequency band 80 MHz … 2 GHz DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-3Test field strength 10 V/mAM 80 % with 1 kHzCriterion AESDDischarge through airTest peak voltage 6 kV8 kV DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-2Contact dischargeTest peak voltage 6 kV4 kVCriterion ATab. 5: Immunity to interference4.4.2 DC power supply inputs and outputsImmunity to inter-ferenceParameter Values StandardsRF field, asymmetric, amplitude modulatedFrequency band 0.15 … 80 MHz DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-6Test voltage 10 VAM 80 % with 1 kHzSource impedance 150 ΩCriterion ABurstsTest voltage 2 kV DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-4tr/tn 5/50 nsRepetition frequency 5 kHzCriterion ASurge voltages, symmetric, line to cableSeries-mode interference tr/th 1.2/50 μs DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-50.5 kVSurge voltages, asymmetric, line to earthCommon-mode interference tr/th 1.2/50 μs DIN EN 61131-2DIN EN 61000-6-2DIN EN 61000-4-51 kVTab. 6: DC power supply inputs and outputs