– 11 Fill up fresh water reservoir. Fresh water container sieve plugged. Thermal protection switch has switchedoff the pump as it was overheated.Switch off appliance and let it cool down(approx. 20 - 30 min). Detergent pump defective, contact Cus-tomer Service. Clean the spray nozzle of the wash noz-zle. Close the surrounding air separator atthe handle. Accessories, suction hose or suctiontubes are clogged, please remove theobstruction. Filter bag is full, insert a new filter bag(for the order no. please see the spareparts list at the end of the present in-structions). Flat fold filter is contaminated, use filtercleaning mechanism, remove the flatfold filter if heavily soiled and clean it(see chapter "Cleaning flat fold filter"). Fill up fresh water reservoir. Use the correct detergent from KÄRCH-ER. Plug in the main plug.Subject to technical modifications!TroubleshootingNo water exiting from nozzleSpray stream unevenInsufficient vacuum performanceDetergent pump noisyStrong foam generation in the con-tainerAppliance is not runningTechnical specificationsVoltage1~50/60 Hz220 - 240 VOutput P nom 1200 WOutput P max 1400 WMains fuse (slow-blow)10 ASound pressure level(EN 60704-2-1)77 dB(A)Weight (without ac-cessories)7,1 kgSpecial accessoriesOrder No.Filter set (5 pc.) 6.904-143.0Flat fold filter 6.414-498.0Washer nozzle for cleaningupholstery2.885-018.0Carpet cleaner RM 519(1 l bottle)International 6.295-771.0Textile waterproofing-agentCare Tex RM 762(0.5 l bottle)International 6.295-769.019ENDownloaded From Vacuum-Manual.com Manuals