8EnglishTroubleshootingCaution:Danger from electrical current. Pull out mainspower plug before any work is carried out onelectrical parts.No water coming out at the nozzle1. Fresh-water tank empty, fill it.2. Nozzle blocked, clean it.3. Suction filter in fresh water tank blocked,clean it.4. Spray pump defective, have it replaced bya technical expert.Spray emitted from one side only1. Nozzle is partly blocked, clean it.Insufficient suction power1. Cover not on properly, put it on properly2. Seal on cover dirty, clean it.3. Fluff strainer dirty, clean it.4. Suction hose is blocked, check and clean it.Spray pump too loud1. Fresh-water tank empty, fill itHave all inspections and work carried out onelectrical parts done by a technical expert.For more extensive tasks contact customerservice.Technical datapuzzi 200 / puzzi 100Voltage variants220/230/240 V (1~50/60 Hz)Power, blower motorSuction turbine P max 1250 WSuction turbine P nominal 1100 WAir flow, max 54 l/sec.Vacuum 220 mbarPower, spray pump, puzzi 200Spray pump 2 x 40 WSpray pressure, max. 2 barSpray quantity 2 l/min.Unit socket, puzzi 200Power consumption, max. 250 WPower, spray pump, puzzi 100Spray pump 40 WSpray pressure, max. 1 barSpray quantity 1 l/min.DimensionsFilling capacity, fresh water 10 lCapacity, dirty water 9 lLength 665 mmWidth 320 mmHeight 435 mmWeight, puzzi 200 12.1 kgWeight, puzzi 100 10.3 kgSound levelConforms to DIN 45635 68 dB(A)Safety class IIMains cableLength 7.5 mType H 05 VV – F 2x1Specifications subject to change without priornotice.Care and MaintenanceCaution:Before any maintenance work takes place,pull the power plug out of the socket.n Check mains cable, connection cable andhoses for damage before putting the unit intooperation for the first time.n Before longer periods of disuse, the entirewater must be drained out of the unitotherwise unpleasant odours might ensue.n From time to time clean the suction strainerin the fresh-water tank and the fluff strainer(Fig. 11).