7.2.2 Error codes iMatch remote controlError code Cause SolutionEntire displayflashing Flat battery Replacing battery.Almost flat battery Replacing battery.NOLK 0 in themiddle of thedisplayControl error Briefly press >NOLK< will appear in the top left corner of the display.NOLKtop left cornerof the displayNo communicationbetween remotecontrol and fireplace(for example in caseof a new remotecontrol)Synchronising remote control:1. Open the hatch of the technical unit and carefully remove the automatic burner relayso it is easily accessible.2. Remove the batteries from the remote control and press (hereby discharging theremote control). Next, replace the batteries into the remote control.3. Isolate the automatic burner relay from power for 20 seconds, this will stimulatethe synchronisation speed. Supply power back to the cable.The entire light will start flashing (once per second). Should the gas fire is providedwith a hybrid function and/or NSG: detach the HCB cable from the automatic burnerrelay.4. Press on the remote control until >NOLK 0< appears on the display.Next, release .5. In case >NOLK 1< or >LINK 1< appear, press again until >NOLK 0< appears.6. Press the black button in the automatic burner relay until the yellow light continuouslystops flashing, then immediately release the black button. The yellow light will startflashing rapidly now.7. Immediately (within 10 seconds) press and hold it down until the word>LINK<starts flashing on the display.8. Wait until >LINK 1< appears and release .9. Press . The normal display with a stationary RF icon will appear once thesynchronisation is successful.10. Reconnect the HCB cable (if applicable).11. Place the automatic burner relay back into the technical unit and close the hatch.02FTemperature of thecircuit board is toohigh1. Turn off the fireplace for approximately 30 minutes.2. Then turn on the fireplace.3. In case the error reappears, there is insufficient ventilation in the chamber of thefireplace.04FNo mains voltagesupply (two-wayswitch only)Supply mains voltage.06ForflashingNo communicationbetween remotecontrol and fireplaceIn case the light on the automatic burner relay (in the technical unit) does not flash:1. Check power supply on the mains (230VAC).2. If this is correct, check/replace the VDC transformer and/or automatic burner relay.In case the light on the automatic burner relay (in the technical unit) flashes:1. Place the remote control as close to the fireplace as possible.2. Briefly press and wait approximately 60 seconds.3. Check the transmission strength. See: Checking transmission strength page 24.Carry out the following steps to check the transmission strength between thefireplace and the remote control.4. Check for objects that could jam the signal (for instance metal casings).5. In case the signal keeps flashing -> synchronise31