HOMEOWNERS GUIDEBath with Airjets1096755-5-D9 of 16Questions? Problems? For additional assistance, please contact KALLISTA’s CustomerService Department at 1-888-4-KALLISTA (1-888-452-5547) or FAX 1-888-272-3094.TROUBLESHOOTING PROCEDURESRotating Ring Key PadPurge ModeDecrease Flow or SurgeIndicator BarIncrease Flow or SurgeSurge ModeZone 3Power On/OffZone 1Air Flow ModeActivates Mode SelectedZone 2Rotate outer ring toaccess desired mode.This troubleshooting guide is for general aid only. A Kallista Authorized Service Representative or qualifiedelectrician should correct all electrical problems. For warranty service, call 1-888-452-5547.Troubleshooting the Bath with Airjets SystemSymptoms Probable Causes Recommended Action1. User keypad does not illuminatewhen power button is pressed orthe outer ring is rotated.A. No power to control. A. Check wiring and connectpower.B. Ground-Fault Circuit-Interrupter(GFCI) or Residual CurrentDevice (RCD) tripped.B. Reset GFCI or RCD. If it tripsagain, refer to “Ground-FaultCircuit-Interrupter (GFCI) orResidual Current Device (RCD)trips when bath with airjets isturned on”.C. Wiring harness from userkeypad to control is loose,disconnected or damaged.C. Check wiring for properconnections. Replace the wiringharness if necessary. Referto your installer or wholesaledealer.D. User keypad does not work. D. Replace the user keypad. Referto your installer or wholesaledealer.E. Control does not work. E. Replace the control. Referto your installer or wholesaledealer.