2CAUTIONNOTICE (NOTE)These international safety symbols are usedthroughout this manual to inform the owner ofimportant safety information and notices forsafe and effective use of the equipment.Important Safety InstructionsCAUTIONUnder NO circumstances should anyone enter•the water with the electrical equipment con-nected and/or in operation. It is NEVER rec-ommended to enter the water with the equip-ment in operation.Caution should be used when dealing with any•electrical equipment with moving parts.NEVER run the unit out of water. It will dam-•age the seals and create a dangerous situationfor the operator.Extreme caution should be used around water,•especially cold water, such as in Spring, Fall,and Winter, which poses a hazard in and ofitself.NEVER lift or drag the unit by the power or•light cord. If you need to pull the unit to theside of the pond, use the anchoring ropes.Do not use waders in deep ponds/lakes or•ponds/lakes with drop-offs, drastic slopes, orsoft bottom material.Do not use boats that tip easily for fountain•installation, such as a canoe, and follow allboating safety rules and regulations, includingwearing a PFD. (Personal Flotation Device)The unit is supplied with an internal ground-•ing conductor. To reduce the risk of electricalshock, be certain that the unit is plugged/con-nected to an approved RCD (GFCI) protectedcircuit.Means for disconnection must be incorporated•in the fixed wiring in accordance with local andnational wiring rules.Consult a qualifi ed electrician for electrical•installation.Unit SpecsModel Voltage Operatingampslock rotoramps2400EVFX 208-240 2.2@240V 6@240V3400EVFX 208-240 3.6@240V 9@240V4400EVFX 208-240 5.9@240V 20@240V2400EJF 208-240 2.2@240V 6@240V3400EJF 208-240 3.8@240V 9@240V4400EJF 208-240 6.5@240V 20@240VQuick Disconnect InstallationImportant – Read Carefully Before InstallationBefore using the connector, it is important that theseinstructions are carefully read and understood toensure the connector system is completely water tightand electrically safe.IF IN DOUBT CONSULT A QUALIFIED ELECTRI-CIAN.The socket (female) insert of the connector must bethe live part of the connector from the supply. The pin(male) insert of the connector must lead to the load orelectrical device. On 50Hz units, the pin (male) insertof the connector is installed at the factory. To ensureefficient sealing, use only smooth circular cable.Pin Insert (Installed on Stub Cord)Pin Insert Main BodyGland Gland NutSocket Insert (User Installed)Socket insert Main BodyGland Gland Nut