32SATCOMMAND OVERVIEW FOR “COMMAND BYTE”The MSK 125 can send commands based on DiSEqC TM1.0, butcannot receive them. All commands that require DiSEqC TM2.0(send and receive) are greyed in the table.Commands shown in bold are preferred for Kathrein switchingmatrices.HexByteCommandnameDescription Number ofdata bytes00 Reset Reset DiSEqC TM microcontroller -01 Clr Reset Clear reset flag -02 Standby Power off peripheral power unit -03 Power on Power on peripheral power unit -04 Set Contend Set the “contention flag” -05 Contend Response only if “contention flag” has been set -06 Clr Contend Clear the “contention flag” -07 Address Response only if contention flag has not been set -08 Move C Change address if “contention flag” has been set 109 Move Change address if “contention flag” has not been set 110 Status Read “status register flags” -11 Config Read “configuration flags” -14 Switch 0 Read “switching status flags” (committed port) -15 Switch 1 Read “switching status flags” (uncommitted port) -16 Switch 2 Expansion option -17 Switch 3 Expansion option -20 Set LO Call “low local oscillator” frequency -21 Set VR Call up vertical polarisation or clockwise circular polarisation -22 Set Pos A Select satellite position A -23 Set S0A Select switch option A -24 Set Hi Call “high local oscillator” frequency -25 Set HL Call up horizontal polarisation or anti-clockwise circularpolarisation-26 Set Pos B Select satellite position B -27 Set S0B Select switch option B -28 Set S1A Call matrix S1 input A (input B inactive) -29 Set S2A Call matrix S2 input A (input B inactive) -2A Set S3A Call matrix S3 input A (input B inactive) -2B Set S4A Call matrix S4 input A (input B inactive) -2C Set S1B Call matrix S1 input B (input A inactive) -2D Set S2B Call matrix S2 input B (input A inactive) -2E Set S3B Call matrix S3 input B (input A inactive) -2F Set S4B Call matrix S4 input B (input A inactive) -30 Sleep All bus commands are ignored except for “Awake” -31 Awake Bus commands are accepted again -38 Write N0 Set port group 0 1