1-800-KEATING |INCREDIBLE FRYING MACHINE™ - SERIES 200613 SERVICE DIAGNOSISThe following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends thatyou use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) Call 1-800-KEATINGif you need assistance in locating a qualifi ed service company.NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order.TROUBLE SHOOTING CHARTPROBLEM PROBABLE CAUSE SOLUTIONMain power light does not come on a. Fryer not plugged in.b. Breaker has tripped.c. Main power switch is faulty.a. Plug fryer to an approved outlet.Must be properly grounded.b. Reset the breaker located on thebottom of the control panel.c. Replace the main power switch.Blower light does not come on a. Thermostat not turned on.b. If blower comes on, blower light isfaulty.c. If Over Maximum Temperature light ison, Hi-Limit has been activated.d. If unit has a fi lter, drain handle notlocked into place.a. Set thermostat to desiredtemperature.b. Replace blower light.c. Reset Hi-Limit after oil has cooleddown below 425°F. Correct problemwhich caused Hi-Limit to activate.(See page 20).d. Secure drain handle in place behindthe bracket.Burner light does not come on • Check for flame at each burner.If no fl ame is present at either burner:a. Spark module is faulty.• Check for flame at each burner.If flame is present at both burners:b. Burner light is faulty.a. Replace spark module.b. Replace burner light.Burner light comes on, then goes out(after 2 1/2 seconds)• Check for spark at each burner.If no spark at either burner:a. Spark electrode wires are not tightor faulty.b. Spark electrode is faulty or is out ofalignment.• Check for spark at each burner.If spark occurs at both burners:c. Gas is not hooked up properly ornot turned on.d. Spark electrode is faulty or is out ofalignment.e. Combination gas valve is faulty.a. Tighten spark electrode wires orreplace.b. See detail on page 27.c. Turn manual gas valve on. If usingfl exible connector with quickdisconnect, make sure that the quickdisconnect is completely engaged.d. Align spark electrode. Replace sparkelectrode if faulty. Gap must be 1/8"between electrode and pilot tube andbetween pilot tube and burner(See page 27).e. Replace combination gas valve afterverifying it has voltage.