WARNINGWHEN YOUR FRYER IS BEING USED INCONJUNCTION WITH A CENTRAL FILTER,DISCONNECT POWER SUPPLY BEFORERESETTING MOTOR TO PREVENT SERIOUSINJURY WHEN RESET SWITCH IS ENGAGED (SEEFILTER MANUAL).16. Check thermostat bulb positioning – see page 10.17. Refill the fryer with new or filtered oil.ELECTRONICTIMERSThe electronic timers provide a clearly visible andaccurate display and are very easy to use. Thisprocedure resets the timer to operate inminutes:seconds.A. TIMER OPERATIONB. How to program the “Keating” ElectronicTimerSTEP 1Make certain power to the timer has been OFF for at least30 seconds. Then PRESS and hold down the UP arrowbutton while turning the rocker power switch to the ONposition.Note: If power switch does not turn off timers, the unit mustbe unplugged (two people may be needed).The timer will turn ON and the display will now be indicatingORThe BEEPER will BEEP 4 times.If STEP 1 was OK, proceed to STEP 2. If not, retry Step 1making sure the power was OFF for at least 30 seconds ormore.STEP 2 PRESS all 3 buttons in sequence: left-center-right.The BEEPER will BEEP when each button ispressed. If BEEPER does not BEEP, the timer isdefective. STOP TESTING. Reset procedure iscompleted when 1:00 appears on the digitaldisplay.IV MAINTENANCEWARRANTYREPAIRSKeating’s warranty begins with the date of installation(or ship date if we are not notified of an installationdate).In the event that your fryer, under warranty, needsrepairs other than routine maintenance or cleaning,you are requested to contact Keating of Chicago(at 1-800-KEATING) before calling a local servicecompany. (Failure to do so may void your warranty).PREVENTIVEMAINTENANCEPreventive maintenance should be done in daily,weekly, monthly and yearly intervals as necessary.Following preventive maintenance procedures will helpkeep your fryer working efficiently. Proper care andservicing will lead to years of quality performance.– – – –– – – –91:00ll