Kelvinator Gas Continuous Flow hot water system for the plumber 5For the plumberPLEASE NOTE this water heater is supplied factory set tocomply with the requirements of AS 3498.If you are installing a 60°C or 70°C gas continuous flow hotwater system, a tempering valve is to be installed for thehot water supplying sanitary fixtures primarily used for thepurpose of personal hygiene.Please follow all the installation instructions in this manualincluding the following instructions regarding the waterheater outlet connection:1. When connecting the hot water supply to the fixtures inthe property, a minimum of three (3) metres of pipeworkmust be used between the outlet of the water heater andthe first tap or outlet. If you are installing a 60°C or 70°Cmodel, only a minimum of one (1) meter of pipework isnecessary. See diagram to the right.2. The hot water outlet line from the water heater should becovered with 20mm pipe insulation or similar to preventheat loss and persons coming in contact with it.3. When the installation is completed, the temperature ofthe hot water supplying sanitary fixtures primarily usedfor the purpose of personal hygiene, for example thebathroom shower/taps, shall be checked to ensure it doesnot exceed 50°C. If a 50°C model gas continuous flow hotwater system has been installed, all hot water taps andfixtures need to be checked to ensure they do notexceed 50°C.MODELSKGC20BNAKGC20KNAKGC20SNAKGC20BLAKGC20KLAKGC20SLAKGC26BNAKGC26KNAKGC26SNAKGC26BLAKGC26KLAKGC26SLACapacity L/min 20L/min 26L/minGas Input MJ/h 160 195Supply Inlet PressurekPa – Nat. Gas1.13 min. 1.13 min.2.75 max. 2.75 max.Supply Inlet PressurekPa - LPG2.61 min 2.61 min2.89 max 2.89 maxWater SupplyPressure kPa150* min 150* min.1200 max 1200 maxHeight mm 542 542Depth mm 170 215Width mm 350 350Weight kg 15.7 17.2Gas Connection mm 20 BSP 20 BSPWater Connections 15 BSP 15 BSPIgnition Electronic ElectronicElectrical Supply Voltage 240 AC 240 ACOperating current 0.8A 0.8A*The water heater will operate at reduced performance if inlet water supplypressure is below 340 kPa.Note: If the gas supply pressure exceeds the maximumvalue in the above table for the respective gas type, fit anappropriate pressure limiting valve at the inlet to the gas inletof the water heater.• For information relating to burner test point pressuresand injector sizes refer to the rating plate located on theright hand side of the cabinet for each model (pleaserefer to the diagram at the bottom of this page showingthe locations of the labels on the water heater).• For information relating to overall dimensions andconnection points refer to diagrams on pages 6 & 7.• Before installing in areas over 1500 m above sea level,contact the manufacturer for instructions.• Total length to first tap or outlet is required to be aminimum of 3 metres from the outlet connection ofthe water heater (minimum 1 metre for 60°C and 70°Cmodels).• Pipe size is nominal 1/2" from hot water outlet to the firsttap or outlet.Accessories4 tapping screws are included with the water heater.Rating labelpositionSerial numberlabel positionGas type labelposition