EN6. teChniCal dataKempoweld 3200 3200WConnection voltage3 ~ 400 V 380 V -10 % ... 415 V +6 % 380 V -10 % ... 415 V +6 %3 ~ 230 V 220 V -10 % ... 240 V +6 % 220 V -10 % ... 240 V +6 %Connection capacity 230 V / 400 V40 % ED 13,6 kVA 13,6 kVA60 % ED 10,0 kVA 10,0 kVA100 % ED 6,6 kVA 6,6 kVAMain cable / fuses220 - 240 V 4 x 2,5 mm² / 20 A delayed 4 x 2,5 mm² / 20 A delayed380 - 415 V 4 x 2,5 mm² / 16 A delayed 4 x 2,5 mm² / 16 A delayedConnection to wire feeder unit 30 V / 250 VA 30 V / 250 VA- Fuse delayed 8 A 8 ALoading capacity (nominal values)40 % ED 320 A / 32 V 320 A / 32 V60 % ED 265 A / 27 V 265 A / 27 V100 % ED 205 A / 24 V 205 A / 24 VControl range 40 steps 40 – 320 A / 15 – 32 V 40 – 320 A / 15 – 32 VOpen circuit voltage 40 steps 15 – 40 V 15 – 40 VOpen circuit power < 50 W < 50 WEfficiency 320 A / 32 V 75 % 75 %Power factor 320 A / 32 V 0,95 0,95Temperature class H (180 °C) H (180 °C)Operation temperature range -20 ... +60 °C -20 ... +60 °CStorage temperature range -40 ... +60 °C -40 ... +60 °CDegree of protection IP23S IP23SEMC class A AMinimun short circuit power Ssc ofsupply network *0.9 MVA 0.9 MVACooling unit power - - - 230 V / 250 VA- Fuse delayed - - - 2 AExternal dimensionslenght 990 mm 990 mmwidth 530 mm 530 mmheight 880 mm 1090 mmWeight 106 kg 118 kg* See paragraph 2.216Kempoweld 3200, 3200W / © Kemppi Oy / 1117