17© Kemppi Oy / 1515ENRestore Settings User 1 (one of ten users) Channel:Selected user can restore to his backup memory channels one by one.Other users’ memory channels remain untouched.Setup settings remain untouched.User 1 (one of ten users) All Channels:Selected user can restore all of his backup memory channels (0-9) at one time.Other users’ memory channels remain untouched.Setup settings remain untouched.Restore To Factory:All channels (of all users) are removed.All users’ backup channels are removed.All setup settings are set to defaults.Licence Menu Licence Code allows you to enter the licence code:- Up/Down arrows are used to select the code number position.- Pulse encoder is used to select the code number (0-255) to be entered.- Soft key button on the right is used to activate the licence number (after all numbers have beenentered). In case the code was wrong the earlier view will be displayed.Licence Timers allows you to check the remaining time of the time-based Wise features.WeldData Delay Adjustment Range:1s – 60s,1s steps.Factory Setting: 20s. Defines how long the Weld Data isdisplayed after Welding Ends.Weld Data display is also turned off whenpulse encoder is turned or any button ispressed.Display Delay Adjustment Range:1 – 20,1 steps.Factory Setting: 10 Defines how long time the information isdisplayed (like: “Setting Saved” text). This isnot always the exact time.Pre Gas Time Pre Gas Time setting:0.0s – 9.9s – CURVE,0.1s steps.Factory Settings: CURVE CURVE: Pre Gas time is read from theWelding program.0.0 – 9.9s: User Pre Gas time setting.Post Gas Time Post Gas Time setting:0.0s – 9.9s – CURVE,0.1s steps.Factory Settings: CURVE CURVE: Post Gas time is read from theWelding program.0.0 – 9.9s: User Post Gas time setting.Control Remote ControlSelection: USER /PANEL / REMOTE /GUN.Factory Settings: USER This setting affects to Welding panel (PF65panel) remote control unit selection.USER: PF65 user can freely select theRemote control device.PANEL: PF65 user can not select the remotedevice. Selection is locked to PANEL.REMOTE: Selection is locked to HANDREMOTE device.GUN: Selection is locked to GUN REMOTEdevice.RemoteAutoRecog Remote AutoRecognition: ON / OFF.Factory Setting: ON ON: Remote control units are recognized.Welding panel (PF65) jumps to PANELselection if the selected remote controlunit disappears. If PF65 USER selection isallowed (see Control).OFF: Remote control units are notrecognized. Remote device selectionremains unchanged if the selected remotecontrol unit disappearsMIG CurrentDisp ON / OFF Factory Setting: OFF ON: Display’s amperage (A) preset valuesOFF: Display’s wire feed speed m/min.