EN4. SETUP FEATURESConfiguring additional featuresThe machine has additional features that can be selected and adjusted with the SETUPfeature. To activate and deactivate it, press both arrow buttons (3) simultaneously for at least 5seconds.In the SETUP mode, the display will show the name of the parameter to be adjusted and itsnumerical value. Select the parameter to be adjusted with the arrow buttons and change theparameter value with the control knob. The following parameters and values are available:NamedisplayedParametervaluesFactorysettingDescriptionA 1/0 0 End current level selection, 1=I min / 0 =15%b 1/0 1/0*) Open-circuit voltage selection: 0 = 95 V, 1 = VRD 30 V / AU VRD 12 VC 1/0 0 Forced stop during downslope with a brief pressing of the switch,1 = On / 0 = Offd 0...4 1 0 = 4T-LOG, 1 = Minilog, 2 = 4T-LOG + Minilog,3 = Minilog + Search arc, 4 = 4T-LOG_4E 5% ... 40% 20% Start current level selection (% of the welding current)F 1/0 0 Restore factory settings **), 1 = Restore / 0 = No restoreh 0.0...2.0 s 0 Minimum setting for pre-gas timeJ 0...10 s 1 s Minumum setting for post-gas timeL 5...20 s 10 s Maximum setting for pre-gas timeo 15...99 s 30 s Maximum setting for post-gas timeS -3...5 0 Arc dynamics (Arc Force)t -9...0 0 Electrode ignition pulse (-9 = No pulse / 0 = Max pulse)*) Factory setting is 1 or 0 depending on the country where the product is sold. Restoring factory settings does not changethe value of this parameter.**) Happens when exiting SETUP mode and value is 1.13© Kemppi Oy / 1201