Man-1078_Sigma_CP_22Page 18 of 2461 CONFIGURE Z1 FOR I.S BARRIER Detection threshold changed for use with IS barrier62 CONFIGURE Z2 FOR I.S BARRIER63 CONFIGURE Z3 FOR I.S BARRIER64 CONFIGURE Z4 FOR I.S BARRIER65 CONFIGURE Z5 FOR I.S BARRIER66 CONFIGURE Z6 FOR I.S BARRIER67 CONFIGURE Z7 FOR I.S BARRIER68 CONFIGURE Z8 FOR I.S BARRIERCODE FUNCTION COMMENTS71* ZONE 1 SHORT CIRCUIT INDICATES ALARM Changes the trigger threshold of thezone so that the control panel can beused on older systems that had no shortcircuit monitoring.72* ZONE 2 SHORT CIRCUIT INDICATES ALARM73* ZONE 3 SHORT CIRCUIT INDICATES ALARM74* ZONE 4 SHORT CIRCUIT INDICATES ALARM75* ZONE 5 SHORT CIRCUIT INDICATES ALARM76* ZONE 6 SHORT CIRCUIT INDICATES ALARM77* ZONE 7 SHORT CIRCUIT INDICATES ALARM78* ZONE 8 SHORT CIRCUIT INDICATES ALARM81* ZONE 1 NON-LATCHING Renders the zone self-resetting so thatit can be used to receive signals fromother systems and will reset when theinput is removed.Note: It can take up to 20 seconds for zone to reset itself whensounders are operating82* ZONE 2 NON-LATCHING83* ZONE 3 NON-LATCHING84* ZONE 4 NON-LATCHING85* ZONE 5 NON-LATCHING86* ZONE 6 NON-LATCHING87* ZONE 7 NON-LATCHING88* ZONE 8 NON-LATCHING91 ZONE 1 DOES NOT SOUND ALARMS Prevents the zone from operating the two common sounderoutputs.92 ZONE 2 DOES NOT SOUND ALARMS93 ZONE 3 DOES NOT SOUND ALARMS94 ZONE 4 DOES NOT SOUND ALARMS95 ZONE 5 DOES NOT SOUND ALARMS96 ZONE 6 DOES NOT SOUND ALARMS97 ZONE 7 DOES NOT SOUND ALARMS98 ZONE 8 DOES NOT SOUND ALARMSA1* ZONE 1 ANY ALARM DELAYED Zone needs to be triggered for 30 seconds continuouslybefore an alarm is generated.A2* ZONE 2 ANY ALARM DELAYEDA3* ZONE 3 ANY ALARM DELAYEDA4* ZONE 4 ANY ALARM DELAYEDA5* ZONE 5 ANY ALARM DELAYEDA6* ZONE 6 ANY ALARM DELAYEDA7* ZONE 7 ANY ALARM DELAYEDA8* ZONE 8 ANY ALARM DELAYEDC1 ZONE 1 SOUNDERS INHIBITED Enables individual zones to be configured not to operate zonalsounders.On 2 wire “T” series panels this enables individual zones to beconfigured for use with conventional (non 2-wire) detectorbases.SOFTWARE VERSIONS SIGMA242.HEX and above onlyC2 ZONE 2 SOUNDERS INHIBITEDC3 ZONE 3 SOUNDERS INHIBITEDC4 ZONE 4 SOUNDERS INHIBITEDC5 ZONE 5 SOUNDERS INHIBITEDC6 ZONE 6 SOUNDERS INHIBITEDC7 ZONE 7 SOUNDERS INHIBITEDC8 ZONE 8 SOUNDERS INHIBITEDE1* ZONE 1 WILL NOT OPERTATE FIRE RELAY Enables individual zones to be selected to not operate the firerelay. This is sometimes combined with the non-latchingfunction to prevent ring around on interconnected panels.SOFTWARE VERSIONS SIGMA242.HEX and above onlyE2* ZONE 2 WILL NOT OPERTATE FIRE RELAYE3* ZONE 3 WILL NOT OPERTATE FIRE RELAYE4* ZONE 4 WILL NOT OPERTATE FIRE RELAYE5* ZONE 5 WILL NOT OPERTATE FIRE RELAYE6* ZONE 6 WILL NOT OPERTATE FIRE RELAYE7* ZONE 7 WILL NOT OPERTATE FIRE RELAYE8* ZONE 8 WILL NOT OPERTATE FIRE RELAYNOTE: Setting the options marked with asterisks does not comply with EN54-2